Dsp Settings - Kenwood KAC-X4R Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

DSP Settings

Perform DSP settings for channels A, B and LINE OUT.
Setting
1 Slide the DISP switch towards SET.
2 Slide the MODE switch to set the channel ("Ach", "Bch" or "LINE OUT").
3 Turn the control knob, display the item to set and push the control knob.
Repeat this step until the item to set is displayed.
To return to the previous menu, turn the control knob, display "RTN" and press the
control knob.
4 Turn the control knob, display the value to set and press the control knob. The
displayed value is set.
Items and setting values
Item
LN.SEL
LEVEL
FREQ (Hz)
(Mean frequency)
BAND1
(Parametric EQ-1)
Q
GAIN
FREQ
BAND2
(Parametric EQ-2)
Q
GAIN
FREQ
BAND3
Q
(Parametric EQ-3)
GAIN
FREQ
BAND4
Q
(Parametric EQ-4)
GAIN
FREQ
BAND5
Q
(Parametric EQ-5)
GAIN
FREQ
LPF
(Low Pass Filter)
SLOPE
ISF
FREQ
(Infrasonic Filter)
FREQ
HPF
(High Pass Filter)
SLOPE
L
DELAY
R
PHASE
NOTE
• For LPF, HPF must be set to "TH".
• For ISF, HPF must be set to "TH".
• For HPF, LPF and ISF must be set to "TH".
• If LPF and ISF are set simultaneously, LPF frequency cannot be lower than ISF frequency.
NOTE
• If speakers are bridged, set "L" and "R" for "DELAY" to the same value. Effects will not be applied properly if they are set to different values.
• DSP settings will not be cleared even when the reset button is pressed.
8
English
Setting value
ST / CT/SW (Default setting value : ST)
-20 – 0 (Default setting value : 0)
25/40/60/80/100 (Default setting value : 25)
1.0/2.0/3.0/5.0 (Default setting value : 1.0)
-9 – +9 (Default setting value : 0)
150/200/300/400/500
(Default setting value : 150)
1.0/2.0/3.0/5.0 (Default setting value : 1.0)
-9 – +9 (Default setting value : 0)
600/800/1k/1.5k/2k (Default setting value : 600)
1.0/2.0/3.0/5.0 (Default setting value : 1.0)
-9 – +9 (Default setting value : 0)
3k/4k/5k/6.3k (Default setting value : 3k)
2.0/4.0/8.0/10 (Default setting value : 2.0)
-9 – +9 (Default setting value : 0)
8k/10k/12.5k/16k (Default setting value : 8k)
2.0/4.0/8.0/10 (Default setting value : 2.0)
-9 – +9 (Default setting value : 0)
TH/30/40/50/60/70/80/90/100/120/150/180/220/
Low
250 (Default setting value : TH)
500/630/800/1k/1.25k/1.6k/2k/2.5k/3.15k/4k/5k
High
(Default setting value : TH)
−24/−12 (Default setting value : -12)
TH/20/30/40/50/60
(Default setting value : TH)
TH/30/40/50/60/70/80/90/100/120/150/180/220/
Low
250 (Default setting value : TH)
500/630/800/1k/1.25k/1.6k/2k/2.5k/3.15k/4k/5k
High
(Default setting value : TH)
−24/−12 (Default setting value : -12)
0 – 3.9 (Default setting value : 0)
0 – 3.9 (Default setting value : 0)
-180/0 (Default setting value : 0)
Control knob
MODE switch
Ach
Bch
LINE OUT
ST
×
×
(When LN.SEL. is
(When LN.SEL. is
set to "ST")
set to "CT/SW")
×
×
×
×
×
×
×
×
×
×
(L/R is not
differentiated)
×
DISP switch
CTR
SW
(When LN.SEL. is
set to "CT/SW")
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
×
Tabla de contenido