VC 4s Cordless
1. Remove the brush roller using a coin or a straight
screwdriver.
Illustration W
2. Remove the roller lever from the brush roller.
Illustration X
Brush roller
1
Roller lever
2
3. Clean up the winding hair in brush roller and brush
lever.
4. Insert dry or new brush roller into floor nozzle, and
fix the brush roller into place by using a coin or a
straight screwdriver.
Illustration Y
Ensure that the brush roller fits properly.
Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or
in the case of malfunctions not mentioned here, please contact your authorised Customer Service.
Fault
The appliance does not
run.
Suction capacity de-
creases. / Abnormal
sound or operating noise
which becomes louder.
The floor nozzle is shut
down automatically.
The warranty conditions issued by our relevant sales company apply in all countries. We shall remedy possible mal-
functions on your appliance within the warranty period free of cost, provided that a material or manufacturing defect
is the cause. In a warranty case, please contact your dealer (with the purchase receipt) or the next authorised cus-
tomer service site.
(See overleaf for the address)
Troubleshooting guide
Possible cause
Filter set / dust container is missing.
Battery is nearly empty.
The appliance is in danger of overheat-
ing.
Dust container is full.
HEPA filter set or cotton filter is clogged.
It is in danger of overheating.
Warranty
VC 4s Cordless Plus
1. Press the release button, and pull out the roller lever
and brush roller.
Illustration Z
2. Remove the roller lever from the brush roller.
Illustration AA
Brush roller
1
Roller lever
2
3. Clean up the winding hair in brush roller and brush
lever.
4. Insert dry or new brush roller into floor nozzle, and
fix the brush roller into place.
Illustration AB
Ensure that the brush roller fits properly.
Remedy
1. Install the filter set and the dust container
before using the appliance.
1. Charge the battery.
1. Check whether the dust container is
clogged.
2. Clean the dust container.
3. Switch the appliance on again.
1. Check the dust container.
2. Empty / clean the dust container, the HEPA
filter and the cotton filter.
3. Check and clean the cyclone set.
1.Check whether the brush roller is blocked,
and clean the brush roller.
2. Switch on the appliance again.