//FAUCET INSTALLATION
8 – Mount the base through the wall opening. Assemble the
rigid pipe from the nipple at the box to the inlet at the base.
Important: the base should be installed so that it remains
on the horizontal, perpendicular to the wall and that the
finished wall
outside surface of the finished wall falls between the
minimum and maximum lines marked at the base.
9 – Pull the cable of the power supply and the sensor cable
coming from the base to the inside of the box.
10 – Connect the electronic unit's connector coming from
the base to the solenoid's connector.
11 – Place the transformer near the electricity plug and
hide the wire inside the box. Protect the portion of the wire
which runs through the wall with a tube.
12 – Connect the power supply connector from the
electronic unit from the base to the transformer. Assemble
the temporary protective cover to the box.
13 –Once the Works on electricity, plumbing and tiles have
been finished, insert the wall rosette through the base.
14 – Connect the cable leading to the solenoid and the
power supply cable at the spout to those at the base. Fix
the spout by inserting the nipple into the base. Make sure
that this area is clean before proceeding. Secure the screw
with the allen key. Make sure that the aerator at the spout
will be installed facing the washbasin.
54