Connections

Input: Input for the red test lead for voltage, resistance, continuity, capacitance and temperature
measurements.
COM: Input for the black test lead for voltage, resistance, continuity, capacitance and
temperature measurements.

Information about the measurement

To obtain the most accurate measurement possible, place the cable between the clamp jaws as
centrally as possible.
Accuracy:
 (% of the read-off value + number of digits) at 18 ° to 28 °C (64.4 ° to 82.4 °F) and
rel. Humidity < 75%.

AC current

Measurement
range
4 mA
40 mA
400 mA
4 A
40 A
150 A
Frequency response: 40 Hz - 1 kHz
Maximum input current: 150 A AC

DC voltage (automatic range selection)

Measurement range
4 V
40 V
400 V
600 V
Input impedance: 10 M
Maximum input voltage: 600 V DC or 600 V AC RMS.
Testboy
®
TV 217
Resolution
0.001 mA
0.01 mA
0.1 mA
0.001 A
0.01 A
0.1 A
Resolution
0.001 mV
0.01 V
0.1 V
Information about the measurement
Tolerance
LPF (50/60 Hz)
± 2.0 % + 10 digit
± 2.0 % + 5 digit
± 2.0 % + 10 digit
1 V
Wide (40 Hz ~ 1 kHz)
± 3.0 % + 5 digits
± 3.0 % + 3 digits
± 3.0 % + 5 digits
Tolerance
± (0.5 % + 4 digits)