NOTE: Unless otherwise specified, following
generic terms "appliance / unit / product /
equipment / device" appeared in this instruction
manual all refer to the product "Campingaz
BIVOUAC
".
TM
Rate : 189 g/h (2,6 kW) - injector n° 062708
Category : butane direct pressure
Thank you for choosing the Campingaz
A - IMPORTANT: ALWAYS BE CAREFUL
WHEN USING GAS !
The purpose of these instructions is to enable you to
use your Campingaz
BIVOUAC
®
complete safety.
Please read them carefully to familiarise yourself
with the equipment prior to assembling the gas
container.
Please observe these instructions and the safety
measures printed on the Campingaz
PLUS / CV300 PLUS / CV470 PLUS cartridges.
Failure to observe these instructions may result
in the user and people in the immediate vicinity
being put at risk.
Keep these instructions in a safe place so that
you can refer to them if needed.
This equipment must be used exclusively with
Campingaz
CV270 PLUS / CV300 PLUS / CV470
®
PLUS cartridges. Using other gas containers may
be dangerous.
The Société Application Des Gaz accepts no
responsibility where cartridges of any other make
are used.
This equipment must only be used in adequately
ventilated areas (minimum 2 m
a good distance from any flammable material.
Do not use equipment which leaks, functions
incorrectly or is damaged. Return it to your
retailer who will inform you of your nearest after-
sales service.
Never modify this equipment or use it for purposes
for which it is not intended.
Do not use this product in caravans, cars, tents,
huts, sheds or any small enclosed areas.
The product should not be used while sleeping or
left unattended.
This product consumes fuel through combustion
or consumption of oxygen and gives off certain
substances and gas, which could be dangerous
such as carbon monoxide (CO).
Carbon monoxide is an odorless, clear gas that
can cause flu-like symptoms, sickness, illness,
and possibly death if produced inside aforesaid
enclosed areas through use of the product
without proper ventilation.
®
BIVOUAC
.
®
TM
correctly and in
TM
CV270
®
/h/kW) and at
3
5
B - PUTTING INTO OPERATION
Remove the equipment from its protective box.
ASSEMBLING THE FEET
Hold the equipment in one hand, then push one foot
(1) fully into one of the supports (2) until it is locked;
button (3) facing outwards (see Fig. 1).
Repeat this for the other three feet.
Installing the Campingaz
PLUS / CV470 PLUS cartridge
(Where the existing cartridge is empty, read paragraph
D : «Removing the cartridge»).
To install or remove a cartridge, always work in a
well-ventilated area, preferably outside and never
in the presence of a flame, heat source or spark
(lit cigarette, electrical equipment, etc.) at a good
distance from other people and flammable material.
CV270 PLUS / CV300 PLUS /
As Campingaz
®
CV470 PLUS cartridges are valve-operated, they can
be detached from the appliance, easily transported
(even when not empty) and fitted to other Campingaz
appliances in the CV270 PLUS / CV300 PLUS /
CV470 PLUS PLUS range designed to operate
exclusively with these cartridges.
- Check that the gas control valve is fully closed, turn
the control valve handle (4) clockwise until closed
( "-" ) (fig.2). Fully close the control handle to
prevent gas flow.
- Hold the burner (caution - it may be hot!) and gently
screw cartridge (5) into the burner clockwise until
you hear a click (about one sixth of a turn) (Fig.
3). Do not tighten the cartridge further, as you may
damage its valve.
- The equipment is ready for use.
In case of leakage (gas smell before opening the
valve), put immediately the equipment outside, in a
well-ventilated area, without inflammation source,
where it will be possible to locate and stop the lead. If
you wish to check the tightness of the equipment, do
it outside. Do not try to locate a leak with a flame, use
gas leak detection liquid.
CV270 PLUS / CV300
®
®