Mount the Wall Plate
Solid concrete or concrete block
2-1
Mark the wall
2-2
Drill pilot holes
2-3
Insert anchors and lag bolts
6901-002115 <05>
≥41 cm
(16 in.)
[01]
[25]
For assistance in determining wall plate location, see Height Finder at
sanus.com.
Level the wall plate [01] and mark the hole locations.
CAUTION:
Mount the wall plate [01] directly onto the concrete surface.
Minimum solid concrete thickness: 203 mm (8 in.).
Minimum concrete block size: 206 x 206 x 406 mm (8 x 8 x 16 in.).
For all concrete applications, the arm must remain centered in
the wall plate (step 3). Keep this in mind when selecting the wall
plate location.
Minimum horizontal space between fasteners: 406 mm(16 in.).
Drill pilot holes as illustrated.
CAUTION:
Pilot holes MUST be drilled to a depth of 89 mm (3 1/2 in.) using
a 10 mm (3/8 in.) diameter drill bit.
Never drill into the mortar between blocks.
89 mm
(3 1/2in.)
Insert lag bolt anchors [25]. Then insert lag bolts [23] through the
washers [24], wall plate [01], and into the anchors.
CAUTION:
lag bolt. To avoid potential injuries or property damage:
Be sure the anchors [25] seat fl ush with the concrete surface.
[01]
[24]
[23]
13 mm
(1/2 in.)
Avoid potential injuries or property damage!
Avoid potential injuries or property damage!
Improper use could reduce the holding power of the
Tighten the lag bolts [23]
only until the washers [24]
are pulled fi rmly against
the wall plate [01].
DO NOT over-tighten the lag
bolts [23].
10 mm
(3/8 in.)