Nice Moon MOMB Instrucciones Y Advertencias Para La Instalación Y El Uso página 8

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
The zero character is represented by 10 sequences of tones
(*)Note – The MASTER card 1 or MASTER card 2 or the UNIQUE MASTER card
must be used depending on the group to which the card to be counted belongs.
With the UNIQUE MASTER all of the cards are counted independently if they are
only active for command n° 1, command n° 2 or both.
4.3.5 -
PROGRAM THE NUMBER OF TIMES A CARD IS USED
A counter is associated to every card, which reduces every time that the card is
used; it is deactivated when the card reaches zero. The number of factory-set
uses is unlimited. This procedure can be used to program the number of uses
of one or more cards. The maximum value that can be associated is 999, higher
values mean unlimited operations.
01. Pass the MASTER card(*) in front of the reader 4 times;
02. Wait 2 seconds; 3 acoustic tones will follow (enable the hundredths);
03. Pass the desired card in front of the reader. a number of times equal to the
hundredths (10 unlimited operations)
04. Wait 2 seconds; 2 acoustic tones will follow (enable the tenths);
05. Pass the desired card in front of the reader. a number of times equal to the
tenths
06. Wait 2 seconds; 1 acoustic tone will follow (enable the units);
07. Pass the desired card in front of the reader. a number of times equal to the
units
(*)Note – The MASTER card 1 or MASTER card 2 or the UNIQUE MASTER card
must be used depending on the group to which the card to be re-loaded belongs.
4.3.6 -
PROCEDURES FOR BLOCKING AND RELEASING THE
AUTOMATION WITH "MASTER" CARD
The automation can be "blocked" or "released" with this function:
• Block procedure
01. Pass any MASTER card in front of the reader 7 times
02. Place the card in front of the reader again and hold it there
03. Wait for 1 acoustic tone (beep)
04. When the beep has ended, remove the card from in front of the reader
6 – English
• Release procedure
01. Pass any MASTER card in front of the reader 7 times
02. Place the card in front of the reader again and hold it there
03. Wait for 2 acoustic tones (beeps)
04. When the beeps have ended, remove the card from in front of the reader
Note – 3 acoustic tones are emitted (beep) at the end of both procedures, if
they have been performed correctly).
4.3.7 -
PROCEDURE FOR DELETING THE ENTIRE MEMORY
USING "MASTER" CARD
This function can be used to delete all data contained in the reader BM memory.
Attention! – Every time the memory is deleted, reader addressing of the
MOMB from the control unit must take place (see respective manual instruc-
tions).
01. Pass any MASTER card in front of the reader 5 times
02. Wait for 3 acoustic tones (beeps)
03. When the third acoustic tone (beep) has ended, place the card in front of
the reader immediately and hold it there
04. Wait for 5 acoustic tones (beeps)
05. When the acoustic tones (beeps) have ended, remove the card from in
front of the reader
The procedure ends after 3 acoustic tones (beeps) and then 5 slow flashes are
emitted to indicate that the memory is empty.
Recommendation: the deletion of the entire memory also determines the dele-
tion of the MASTER card.
In the PROFESSIONAL mode it is also possible to perform:
– Self-insertion of new cards (see chapter 6.1)
– Delete the data in the BM memory (see chapter 6.2)
– Change the type of command associated to command n° 1 and n° 2 (see
chapter 6.3).
Tabla de contenido
loading

Tabla de contenido