Smart Display SD3
• simultaneous visualisation of collector and store
temperature as well as heat quantity
• one 6-digit and two 4-digit 7-segment LED dis-
plays
1. Installation
1.1 Mounting
wooden rod
2.
Connection and commissioning
• simple connection via RESOL VBus
• outstanding design
• power supply via RESOL VBus
Wall mounting
The wall mounting of the SD3 has to be carried out using
the enclosed high-grade steel bracket.
1. Hold bracket to the desired place on the wall. Mark
drilling holes on the wall and drill holes with a 6 mm
drill.
2. Insert dowels and attach the bracket to the wall with
the screws (accessory bag).
Place the SD3 in the middle of the bracket.
The device must only be located in dry interior
rooms. It is not suitable for installation in hazardous
locations and should be protected from electroma-
gnetic fields.
Use as table-top unit
Insert wooden rod into the lower hole on the rear side of
the housing.
The SD3 can now be placed to the desired place.
Note:
Protect susceptible furniture surfaces against scratches.
The RESOL Smart Display SD3 is designed for simple con-
nection to RESOL controllers via the RESOL
cable can be extended with a two-wire cable (bell wire).
The cable carries low voltage and must not run together in
a cable conduit with cables carrying a higher voltage than
50 V (please pay attention to the valid local regulations
such as VDE regulations for Germany). The cross section
must be at least 0,5 mm
and the cable can be extended up
2
to 50 m in the case of a single connection.
B
®
®
. The bus
VBus
®
7
|