Heath Zenith SL6034 Manual Del Usuario página 4

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

D
B
ual
rite
Light comes on half power for selected time after dusk (Off, 3
hours, until dawn). When motion is sensed, the light turns on full
power for the selected ON-TIME (1 or 5 minutes) then returns
to accent mode.
1. Select amount of time desired for accent lighting (D
control).
• 3 Hours
• Dusk to Dawn
2. Select the amount of time light stays on full bright after motion
is detected (On-Time control).
• 1 Minute
• 5 Minutes
Night only or 24 Hour Mode
This sensor is able to detect motion day and night or night only.
Slide the DETECT switch to either the DAY/NIGHT or NIGHT
ONLY position.
Motion Sensing range Control
Adjust the RANGE dial to increase or decrease the motion sensing
range as needed. Too much sensitivity may cause false triggering
due to heat sources in the coverage area.
The sensor on this light fixture detects "motion" by the movement
of heat (body heat) across the coverage area. However, following
are examples of objects that also produce heat and can cause the
sensor to false trigger:
• Pools of Water
• Dryer Vents
• Heating Vents
If you suspect that a heat source of this type is falsely triggering
the sensor, adjust the RANGE dial as needed to avoid false
triggering.
dimmer Control
®
• Air Conditioners
• Fenced-In Animals
• Automobile Traffic
INStaLLING SoLar MotIoN SENSor
1. Attach the sensor unit to the ground
spike. Note: If you need to raise the
sensor unit an additional 6", use the
extension rod.
B
®
2. Determine where you want to install
ual
rite
the motion sensor. IMPORTANT: Place
sensor where it will be able to receive
 to 6 hours of direct sunlight each
day.
Note: If the sensor does not respond
within 2 minutes after installation, al-
low 1 day for the batteries to charge.
Continue with testing after the batteries
have been completely charged.
3. Aim the sensors in the direction of
desired coverage. Note: The sensors
have a greater range directly in front
of them than they do to the sides.
. While holding the ground spike in the direction determined,
remove the sensor unit (and extension rod if attached).
5. Place the ground spike on the ground and press into the soil.
If necessary, use a rubber mallet to drive the ground spike into
the ground.
6. Reattach the sensor unit (and extension rod, if applicable) to
the ground spike.

Sensor Unit
Sensors
Extension Rod
Ground Spike
598-1271-01
Tabla de contenido
loading

Este manual también es adecuado para:

Sl-6037-wh

Tabla de contenido