INSTRUCTION MANUAL
PRODUCT'S PRESENTATION
This product has been designed to disinfect the air
in rooms, using ozone (O3) and UV light to oxidize
almost any particle (including viruses, bacteria, or-
ganic and inorganic compounds).
SAFETY INSTRUCTIONS
For sterilization, please only use in unoccupied
space.
Ozone with high concentration has adverse
effects on human health. Therefore, the use of ozo-
ne for air disinfection is generally not recommen-
ded if people are around.
Therefore, air disinfection using ozone should
be restricted to unoccupied room only
It is important that the ozone air purifier be properly
grounded to avoid potential shock.
Before entering in a disinfected area, you should
wait for approximately one hour to make sure ozo-
ne levels are not harmful to human health.
To know the exact concentration of ozone in the
air, you can use an ozone meter (REF.53802).
If you need to enter the area while disinfecting
it, make sure you wear suitable personal protective
equipment.
OPERATION
Make sure the area is unoccupied before using.
Set the type of disinfection you need:
• Low: Ozone production 10000mg/h
• High: Ozone production 20000mg/h
NOTE: If you use the "Ion" disinfection, it is not
harmful to human health, so it can be used while
people is around.
If you use the other two settings ("Ozone" or "Ion +
ozone"), you have to make sure the room is unoc-
cupied.
Turn the timer clockwise to set for how long time
you need the product to run.
After setting the time, the indicator light will turn on
and the generator will begin to work.
When time is up, the indicator light will turn off and
the generator will stop working.
If you need the air purifier to run indefinitely, turn
the timer clockwise to the "hold" position.
To power off the product, set the dial to the "off"
position.
Recommended operating time for different room
volume:
500m³
600m³
30min
40min
50m³
100m³
8min
16min
UV lamp
If you want to activate the UV lamp, put the switch
in UV position.
MAINTENANCE
Ozone plate:
Clean the ozone plate about once every month.
It is better to replace it every half year (REF. 14802).
Clean or change the ozone plates as follows if the
ozone output is weak.
To take out the plate, do as shown below:
Clean the plate with water or replace with a new
one.
Before placing the plate, make sure it is dry.
Air-filter:
Air-filter is washable. You can clean if dirty.
· 4 ·
700m³
800m³
900m³
50min
60min
70min
150m³
200m³
300m³
24min
32min
48min
REF. 53806
1000m³
80min
500m³
65min