EN
Technical data
Interval flush factory setting
Interval flush adjustment range
Flow rate at 1 bar with/without flow limiter
Maximum test pressure water
Maximum test pressure air/inert gas
Detection time factory setting
Detection time adjustment range
Nominal voltage
Mains frequency
Battery type
Alkaline manganese battery service life
Power consumption
Protection degree
Operating voltage
Flush time factory setting
Flush time adjustment range
Relative humidity
Operating pressure
Maximum operating temperature water
12
Mains operation
24 h
1–168 h
0.3/0.24 l/s
16 bar
1600 kPa
3 bar
300 kPa
7 s
3–15 s
110–240 V AC
50–60 Hz
–
–
< 0.5 W
IP45
4.5 V DC
4 s
1–15 s
< 100%
1–8 bar
100–800 kPa
30 °C
Battery operation
24 h
1–168 h
0.3/0.24 l/s
16 bar
1600 kPa
3 bar
300 kPa
7 s
3–15 s
–
–
Alkaline manganese
battery 1.5 V (AA)
~ 2 years
< 0.5 W
IP45
3 V DC
4 s
1–15 s
< 100%
1–8 bar
100–800 kPa
30 °C
B1255-001 © 08-2015
966.920.00.0 (00)