Fein KBM32Q Manual De Instrucciones página 11

Ocultar thumbs Ver también para KBM32Q:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3 41 01 011 21 0.book Seite 11 Montag, 8. Februar 2010 11:51 11
Assembly instructions.
Before mounting or replacing application tools or accessories, pull the power
WARNING
plug. This preventive safety measure rules out the danger of injuries through
accidental starting of the power tool.
Mounting the cooling lubricant pump
(Figure 2).
Prevent the flow of liquid
WARNING
along the cable into the socket
or into the core drill, as this can lead to elec-
tric shock. Tie a bow in the cable near the
plug, so that any liquid can drip off.
Only use cooling lubricant that is capable of
being pumped.
Insert the filled cooling lubricant pump
into the holder on the drill stand housing
intended for this purpose.
Connect the cooling lubricant hose.
Mounting the contact and swarf
protector (Figure 3).
The contact and swarf protector must be
mounted for all work.
Mount the contact and swarf protec-
tor.
For removal of collected swarf, fold
out the contact and swarf protector.
Before starting the working proce-
dure, lock the contact and swarf protec-
tor with the hook.
Fig. 2
Cooling lubricant connection
Fig. 3
Contact and swarf protector
en
11
Hook for
locking
Tabla de contenido
loading

Este manual también es adecuado para:

7 270 27

Tabla de contenido