Tabla de contenido
Idiomas disponibles

Idiomas disponibles

6.2.2 Run the unit for several minutes without load to cool down the generator set.
6.2.3 Set the ignition switch to OFF position(Figure 35)
6.2.4 Set the fuel switch to OFF position (Figure 36)
WARNING Don't touch the heating components before the unit cools down
after stopping the engine to avoid burns.
CAUTION Fuel storage in unit which is not to be used for long time will
cause it difficult to start the engine. Drain the fuel for long-time storage of
the unit.

7 Maintenance

7.1 Maintenance Schedule: The Unit should be serviced according to the following
Maintenance Schedule:
Perio
d
Item
Check engine oil
Replace engine oil
Check air cleaner
Wash air cleaner
Oil filter cover
Battery electrolyte
level
Spark plug
Each
20 Hrs or
Time
1st Month
Check
Replace
Check
Check
50Hrs or Every
3 Month
Clean
17
100Hrs or
300Hrs or
every 6
every one
Month
Replace
Clean
Clean
year
Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Kz10000e

Tabla de contenido