BUTTON FUNCTION

Press the ORIGIN button to zero the micrometer.
CAUTION! The LCD automatically turns off if it
has been idle for 20 minutes. To turn on the
LCD, turn the thimble.
ZEROING THE MICROMETER
IMPORTANT! When the battery has been
installed, first press the ORIGIN button, but
do not rotate the thimble while the preset
values are being set. (See Figure 1) Rotating
the thimble during this time may result in the
failure of setting the default settings. Reinstall
the battery if you moved the thimble during
this time.
• Before measuring check the origin (zero point)
according to Figure 3.
• Remove dust/oil from the measuring faces before
zeroing the micrometer.
• It is recommended that the micrometer is held in the
same position and under the same conditions for
both zeroing and actual measurement.
ERROR MESSAGE
Err-oS
Err-S
If the problem persists, or if the troubleshooting section does not resolve or describe your problem, contact
Uline Customer Service at 1-800-295-5510.
PAGE 3 OF 9
OPERATION
Zero the micrometer by following the procedure below:
(See Figure 3)
1. Turn the thimble to gently bring the spindle into
2. Press the ORIGIN button.
3. If 0.000 is displayed and "P" is flashing, press the
4. "P" disappears, indicating the micrometer has zeroed.
TROUBLESHOOTING
OPERATING ISSUE
The battery is depleted.
Error indicates when a counting error
occurred due to noise or moving
spindle too fast.
Error indicates when a counting
error occurred due to an error in the
electronic unit during the initial setting
of the micrometer.
1-800-295-5510
uline.com
1
Figure 3
contact with the anvil. Apply the rated measuring
force using the ratchet stop/friction thimble.
ORIGIN button again. The display value will not
change while "P" is flashing.
CAUTION! If the ORIGIN button is accidentally
pressed during measurement, press the ZERO/ABS
button to restore. Zero the micrometer again if
measurement function is still not restored.
RECOMMENDATIONS
Replace the battery.
Reset the battery and zero the
micrometer.
Reset the battery and zero the
micrometer.
2
3
ORIGIN
4
ORIGIN
0421 IH-2780