Once you have completed the installation of the dryer,
use this test to make sure the condition of the exhaust
system is adequate for proper operation of the dryer.
This test should be performed to alert you to any serious
problems in the exhaust system of your home.
• Your dryer features Sensor de Flujo (Flow Sense), an
innovative sensing system that automatically detects
blockages and restrictions in dryer ductwork. Keeping
ductwork clean of lint buildup and free of restrictions
allows clothes to dry faster and reduces energy use.
NOTE
F
The dryer should be cool before starting this test. If
the dryer was warmed up during installation, run the
Secado con Aire (Air Dry) cycle for a few minutes to
reduce the interior temperature.
To activate the installation test:
1. Remove the literature, and then close the door.
Do not load anything in the drum for this test, as in
may affect the accuracy of the results.
H
B
2. Press and hold the Control Temp. and
Alarma(Signal) buttons and then press the
ENCENDIDO/APAGADO (POWER) button.
This button sequence activates the installation test.
The code
successful.
3. Press INICIO/PAUSA(START/PAUSE) button.
The dryer will start the test, which will last about
two minutes. The heat will be turned on and the
temperatures in the drum will be measured.
MFL70442615_en_190426.indd 35
G
D
A
C
will display if the activation is
INSTALLATION INSTRUCTIONS
F
4. Check the display for results.
During the three minute test cycle, monitor the
Sensor de Flujo (Flow Sense) display on the control
panel. If no bars are displayed, when the cycle ends,
the exhaust system is adequate. If the exhaust
system is severely restricted, the display will show
four bars. Other problems may also be shown with
error codes. Refer to the next page for error code
details and solutions.
E
H
nO BARS:
OK
Four bars indicates that the exhaust system is severely
restricted. Have the system checked immediately, as
performance will be poor.
5. End of cycle.
At the end of the test cycle,
The test cycle will end and the dryer will shut off
automatically after a short delay.
D
35
A
B
C
FOUR BARS:
RESTRICTED
will display.
2019.4.26 9:54:37 AM