Exiting installer mode:
Minimum on or off time of the boiler
Number of cycles per hour
Proportional band
Probe calibration
Maximum set temperature
Minimum set temperature
Activation of Air conditioning mode
Temperature of frost protection mode
Electrical heating
Factory reset
Applications
Gas Boiler (<30 kW)
Oil Boiler - Heat pump -
Pellets stove
Type of Control
Electrical protection
Type of Batteries
Temperature range
Action
Rated current
Environment
Regulation class
(according 811/2013)
Energy effi ciency gain (contribution to seasonal space heating energy effi ciency)
Class of Software
Supplier
Warranty
The warranty does not cover problems related to improper installation, incorrect wiring or improper use.
Processing waste of electronic and electric devices at life-cycle end.
This image indicates that this product must not be disposed of with unsorted home trash. A
system for disposal and special processing of used electric and electronic devices, manda-
tory to follow, has been implemented including the right to have vendors retrieve free-of-
charge used appliances upon purchase of new appliances, as well as special collection of
such waste by approved organisations.
For more information on this, you can contact your store or your town hall. Proper disposal of used elec-
tric and electronic appliances ensures their adequate processing and recycling in order to avoid damage
to the environment and public health as well as to preserve natural resources.
Description
Cycles /Hour
6
3
Technical data
Independently mounted control for Surface mounting
IP30
No protection against water ingress
CLASS II
Product that does not incorporate protective earthing provision,
but a double insulation as provision against electric shock
2 batteries AA (LR06 ) 1,5 V (not supplied)
5-35°C
Micro-interrupt, Type 1 .C
Rated voltage : 24-230V~, 50-60Hz - Max rated current for Resistive load : 8A
Max rated current for Inductive load : 3A
Pollution degree = 2 (standard household conditions without conductive dust)
Class IV
Class A
ADEO Services - 135 Rue Sadi Carnot, CS 00001, 59790 - RONCHIN - FRANCE
3 s
Plage de valeurs
1, 2, 3, 4, 5 min
3, 6, 9, 12
1.5 .... 3.0 °
-3.0 .... +3.0 °
21 .... 35 °C
5 .... 21 °C
0, 1 (1 = Activated)
--(Off ), 5 .... 16 °C
0 (<3A) / 1 (3A-8A)
0 / 1
Minimum ON time
Parameters to be changed
1 min
4 min
Rated impulse voltage
Overvoltage Category according IEC/EN 60730-1 II
Valeur d'usine
1 min
6
1.5 °
0
35 °C
5 °C
0
5 °C
0 (<3A)
1 (reset)
No change
Parameter Ot on 4
Parameter Cr on 3
2500 V
2%
FR
ES
PT
IT
EL
PL
UA
RO
EN