Exchanging The Flat Pleated Filter; Change Safety Filter Bag/Dust Bag - Baier BSS 608H Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 65
WARNING
Safety equipment for preventing hazards
must be serviced and maintained regularly.
This means that the manufacturer's staff or
persons trained by the manufacturer must
check the equipment for proper functioning
at least once a year, i.e. check for leaks, fil-
ter damage, functioning of the controlling
elements, etc.
DANGER
You can test the filtration capacity of the de-
vice using the test procedure specified in
EN 60 335–2–69 22.AA.201.2. This test
must be done at least once a year or more
frequently if the national regulations demand
it. If the test results are negative, the test is
to be repeated with a new flat-fold filter.
Note: Industrial vacuum cleaners/dedust-
ers must be maintained as needed, but at
least once per year, repaired as necessary
and checked by a skilled expert (qualified
as per TRGS 519 Nr. 5.3, paragraph 2).
The test result must be presented upon re-
quest.
ATTENTION
Risk of damage! Do not use detergents
containing silicone to clean.
– No outside help is required for carrying
out basic maintenance and cleaning.
– The appliance surface and the inside of
the container should be cleaned regu-
larly using a damp cloth.
DANGER
Risk due to dust hazardous to health. Al-
ways use disposal clothing and P2 or higher
breath-safe masks while carrying out main-
tenance tasks (such as changing filters).

Exchanging the flat pleated filter

DANGER
The dust that has been collected should be
transported in dust-proof containers. No re-
filling is permitted. The waste containing as-
bestos is to be disposed off according to the
rules and regulations for waste disposal.
WARNING
Do not reuse the main filter element after it
has been removed from the appliance.
24
Non-detachable filters should only be re-
placed in suitable rooms (so-called decon-
tamination stations) by an expert.
Item no. flat fold filter (PES): 9470
Item no. flat fold filter (GS): 9469
Illustration
 Rotate both locking lugs of the filter cov-
er using the screwdriver in the anti-
clockwise direction. The locking lugs
are pushed out.
 Open filter door.
Illustration
Q
 Remove filter frame/filter holder unit.
 Remove flat fold filter (GF).
 Unlock the bar and remove the filter
holder.
 Remove flat fold filter (PES).
 When removing the respective flat fold
filter wrap this immediately with the bag
provided and seal it.
Item no. bag: 9107
 Dispose of the respective used flat fold
filter in the dust-proof sealed bag in ac-
cordance with statutory provisions.
 Remove the dirt that has accumulated
on the pure air side.
 Insert the new flat fold filter.
During insertion, ensure that the re-
spective flat fold filter is flush on all
sides.
 Insert the filter holder and lock using the
bar.
 Insert the filter frame/filter holder unit.
 Close the filter door, it must lock into
place.
 Push both locking lugs of the filter cover
in with the screwdriver and tighten them
in a clockwise direction.

Change safety filter bag/dust bag

Close the suction connection
Illustration
 Close the suction connection, see wet
vacuuming.
– 7