SentrySafe QAP2E El Manual Del Propietario página 6

The Problem:
Why It Is Happening:
Red LED blinks
Incorrect code has
three times
been entered
Programming error
Red LED slowly blinks for
An incorrect code has been
two minutes
entered five times
Red LED blinks once every
Battery power is low
ten seconds
Red LED blinks five times
System error: power failure
Cannot open the lid after
Batteries have reached
entering the code
end of life
After code entry, lid does
Incorrect code entry
not open, backlights stay
on, then turn off, red LED
blinks three times
Lid does not open when
Gas strut has stopped
using override key
working
LED interval will not
Incorrect code entry
reprogram
10
The Solution:
Verify the code and re-enter
or reprogram (see page 4)
Wait for two minutes or use
the override key to access
the safe (see page 7)
Replace with four AA
alkaline batteries (do not
use rechargeable batteries
or any other type of
non-alkaline battery)
(see page 4)
Re-enter the code with
distinct key presses
(see page 7)
Use a magnet to open the
lid. Turn unit upside down
for lid to open. Contact
SentrySafe Customer Service
for support.
Close the lid and follow
Programming Method
for Interior LED Interval
instructions (page 6)
How to obtain a replacement key
11
loading

Este manual también es adecuado para:

Qap2el