Turning On/Off - Milwaukee M12 ONEFTR38 Manual Original

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 36
View recent
Recall recent history from a previous
history
time frame.
Settings
View sub categories within the settings
function.
Units
Select units; ft-lbs, in-Ilbs, Nm and
kg-cm
Sound & Haptics
Change ON/OFF options to light,
sound and haptics.
Screen Brightness
Select between low, medium and high
screen brightness modes.
Screen Display
Select light or dark backlight display.
Language
Change the language setting
Rundown Torque
Add a percentage to the total selected
torque. Tool will stop at or near the
percentage allowing user to hand
tighten for full torque. (See "adjusting
rundown torque")
About
General information for a certifi cation
count and fi rmware.
Certifi cation
Display the last certifi ed date and a
Count
count until the next certifi cation is
required. (See "certifi cation" section for
more information.)
Firmware
Displays fi rmware version and tool part
number.
Modes
Use the modes function to set up a profi le quickly within a
couple of steps. Within the modes option: set up units,
target torque and percentage range. Once the mode is
selected: apply, edit or delete a mode.
Saved Events / Grouping
Save events to use at a later date. Storing in a group will
make it easier to recall preset specifi cations. The tool will
not automatically save events. From the main screen, use
the left and right arrows
To open a group and include saved events within the
group. Press and hold the save button
ONE-KEY™
We considered the results to be within our minimum
acceptable performance level according to EN 55014-
2:2015 / EN 301489-1 V2.1.1 / EN 301489-17 V3.1.1.

TURNING ON/OFF

Hold tool motionless when turning the tool ON. Movement
during the initial two second sensor check may aff ect
torque value.
Press the power button
Press and hold the power button
The tool will go into standby mode within 2 minutes of
nonuse and sleep mode after 10 minutes.
NOTE: In standby mode, pressing the paddle switch or
power button will turn the tool back on. In sleep mode,
pressing the power button will turn the tool back on.
APPLICATIONS
Making a simple measurement
1. Select the units of measure.
2. Set the target torque.
3. Apply torque. Hold the center of the trigger handle and
pull the trigger. While the trigger is pulled "- - -" is
18 ENGLISH
470 221 - M12 ONEFTR38, M12 ONEFTR12.indd 18
470 221 - M12 ONEFTR38, M12 ONEFTR12.indd 18
and select the save button
for 3 seconds.
to turn the LCD ON.
to turn the LCD OFF.
displayed. The tool will automatically stop before target
torque is reached to prevent over torquing.
NOTICE! Do not hold the to tool by the boot while
applying torque. lt will aff ect the accuracy of the tool and
could give inaccurate readings.
4. Finish by hand to reach target torque. Current torque
value is displayed.
5. Press
to save an event, to stay consistent with the
tool.
6. Release torque. The torque reading on the LCD will
display for > than 5 seconds or the next trigger pull.
Adjusting torque range
zzTorque range indicates the acceptable range of values
for a successful install. Adjust the torque range to meet the
recommended torque specifi cations.
Adjusting rundown torque
Rundown torque is the approximate torque value the motor
will stop driving the tool. The tool will tighten the fastener to
the selected preset percentage and then stop. Finish by
hand to reach target torque.
NOTE: Rundown torque changes the tools output power.
Adjust the rundown torque to help prevent over Adjusting
torquing target of the torque fastener.
Adjusting target torque
Target torque is the required torque value for the fastener
being installed. Adjust the target torque to meet the desired
torque specifi cations.
DISPLAY ALERTS
.
Memory Almost Full
Connect to this tool with the One-Key
Dismiss
Dismiss
Memory Full
Connect to this tool with the One-Key
to sync history of events
Dismiss
Dismiss
Battery Over Temperature
Dismiss
Dismiss
Memory for Saved
Events The tool has a limited
amount of memory dedicated to
saved events. When keeping a
prolonged list of events outside of
the tools memory, refer to the
ONE-KEY™ app for better
backup. To clear your saved
events, connect to the ONE-
KEY™ app and clear the memory
on the tool using the app. This
ensures that the events are
backed up online within the
ONE-KEY™ cloud.
NOTE: The display will prompt
that the memory is close to being
full or reached capacity.
Over Temperature
If the tool overheats, a warning is
displayed. Turn OFF the tool and
allow it to cool before continuing.
08.11.2019 09:22:01
08.11.2019 09:22:01
Tabla de contenido
loading

Este manual también es adecuado para:

M12 oneftr12M12 oneftr12-0cM12 oneftr12-201c

Tabla de contenido