3
Mounting and installation instructions
Warning
Before carrying out assembly, installation and
maintenance work, always switch off the operating and
compressed air supplies.
Warning
If an axis is fitted in a sloping or vertical position, the
work load may slide down.
S Check whether external safety measures are neces
sary (e.g. toothed latches or moveable bolts).
This prevents the work load sliding down suddenly if
there is a power failure.
Warning
Use only power units which guarantee reliable
electrical isolation of the operating voltage as per
IEC/DIN EN 60204−1. Observe also the general
requirements for PELV power circuits as per
IEC/DIN EN 60204−1.
Use regulated power supply with high performance
S
curve.
To prevent earth loops: Use only one of the earth
S
terminals.
Seal unused terminals with the protective caps
S
supplied.
Festo GDSP−SFC−LACI−ML 0812NH English
23