13
TECHNICAL DATA
14
Max. response time
Enclosure rating
5)
Protection class
Circuit protection
Ambient operating temperature
1)
Limit values; terminal connection: permissible wire cross-sections 0.14 to 1.5 mm
≤ 4 A
2)
Usage category: AC-15, DC-13 (EN 60947-1)
3)
With light / dark ratio 1:1
4)
Signal transit time with resistive load
5)
Pursuant to EN 60529
6)
Replaces IP69 K pursuant to ISO 20653: 2013-03
7)
Rated insulation voltage U
250 V, overvoltage category II
i
8)
A = U
-connections reverse polarity protected
B
B = inputs and output reverse-polarity protected
C = Interference suppression
WL24-2B / -2V
-2R
≤ 500 µs
≤ 10 ms
4)
4)
-2B2x0, -2B3x3,
-2R2x0, -2R5x8:
-2V2x0: IP67
IP67
-2B4x0, -2V5x0:
IP69
6)
II
II
7)
7)
A, B, C
A, C
8)
8)
–40 °C ...
–40 °C ...
+60 °C
+60 °C
; male connector:
2
8008783.14BT | SICK
Subject to change without notice