Philips GC9400 Serie Manual Del Usuario página 7

Ocultar thumbs Ver también para GC9400 Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 15
2 When no more water comes out of the appliance, reinsert the EASY DE-CALC knob and tighten it
(Fig. 19).
Descaling the soleplate
If you do not descale your appliance regularly, you may see brown stains coming out of the soleplate
due to scale particles. Descale the soleplate by following the procedure below. We advise you to
perform the procedure twice for better results.
1 Make sure the appliance is cool and clean the soleplate with a damp cloth.
2 Empty the water tank through the filling door (Fig. 20). Tilt the appliance and remove the EASY DE-
CALC knob.
3 Pour 500ml distilled water into the DE-CALC opening and tighten the EASY DE-CALC knob (Fig. 21).
4 Fill up the water tank halfway. Switch on the appliance and wait for 5 minutes.
5 Keep the steam trigger pressed continuously while you iron a few pieces of thick cloth in a back-
and-forth motion for 3 minutes (Fig. 22).
Warning: Hot, dirty water (about 100-150 ml) comes out of the soleplate.
6 Stop cleaning when no more water comes out of the soleplate or when steam starts coming out of
the soleplate.
7 Unplug the steam generator and let it cool down for at least two hours. Remove the EASY DE-CALC
knob and let the remaining water flow out. Tighten the EASY DE-CALC knob.
Storage
1 Switch off the appliance and unplug it.
2 Pour the water out of the water tank through the filling door (Fig. 20).
3 Fold the supply hose.
4 Wind the supply hose inside the supply hose storage compartment (Fig. 23).
5 Fold the mains cord and fasten it with the Velcro strip.
6 Place the iron on the iron platform and lock it by pushing the carry lock release button (Fig. 24).
7 You can carry the appliance with one hand by the handle of the iron when the iron is locked on the
iron platform (Fig. 25).
Troubleshooting
This chapter summarizes the most common problems you could encounter with the appliance. If you
are unable to solve the problem with the information below, visit www.philips.com/support for a list
of frequently asked questions or contact the Consumer Care Center in your country.
Problem
Dirty water, brown stains
or white flakes come out
of the soleplate.
There is no or little steam. The appliance has not heated up
Cause
Scale has built up inside the
appliance because it has not been
descaled regularly.
You have put chemicals or additives
in the water tank.
sufficiently.
English
Solution
Descale the appliance and the
soleplate (see chapter 'Cleaning
and maintenance').
Never use chemical or additives
with the appliance. If you have
already done so, follow the
procedure in chapter 'Cleaning
and maintenance' to remove the
chemicals.
Wait until the iron ready light
stays on continuously. This takes
approx. 2 minutes.
9

Hide quick links:

Tabla de contenido
loading

Este manual también es adecuado para:

Gc9300 serieGc9330/20

Tabla de contenido