Installation and Sensitivity Adjustment
Install the detector on the ceiling or walls adjacent or opposite to
the protected glass. Avoid proximity to noisy objects such as bells,
fans, compressors, and loud machinery. Make sure the microphone
has a direct and unobstructed view of the protected glass.
Installation steps:
1.
Connect the AC adaptor with the connector of the detector. Then
plug the AC adaptor into wall socket.
2.
Clean the surface of the locations you are going to install.
3.
Use the double-sided tape to fix the product on the installation site.
You can set sensitivity of detector based on requirements. If the
environment produces echoes easily, adjust sensitivity to low; if the
environment has damping materials, adjust the sensitivity to high.

Installation Diagram

Connect with the Control Panel
Please connect the detector with control panel before use:
Make sure the control panel is under connecting state. Press the
rear tamper switch of the detector, the control panel receives
wireless signals from the detector and beeps once. Connection
succeeded. Arm the alarm system and trigger the rear tamper
switch of the detector again, the siren of control panel will hoot to
indicate they have been connected successfully.
Specifications
Power Supply:
DC 12 V 500 mA
Static Current:
< 2.6 mA
Alarm Current:
< 28 mA
Detection Distance:
Max. 7 m
Transmitting Distance:
< 80 m (in open area)
Radio Frequency:
868 MHz or 915 MHz
Housing Material:
ABS plastic
Operation Condition:
Temperature: 0 °C ~ + 55 °C
Relative Humidity: < 80% (non-condensing)
Detector Dimensions (L x W x H):
54 X 15 X 106.5 mm