The multi−I/O module (12I/8O, PNP/NPN) is intended ex
clusively for valve terminals types 03..04 and type 44/45
(VTSA/VTSA−F). The specified limits in the technical data
must be observed.
Detailed information can be found in the supplementary
description P.BE VIEA−03/05.... .
Warning
S Switch off the power supply before connecting or
disconnecting plugs (otherwise this could lead to
functional damage).
S Use power supplies which guarantee reliable electri
cal isolation of the operating voltage as per IEC/DIN
EN 60204−1. Consider also the general requirements
for PELV circuits in accordance with IEC/DIN EN
60204−1.
S Connect an earth conductor of sufficient diameter to
the connection marked with the earth symbol.
Note
Only operate a valve terminal which is completely fitted
and electrically wired.