PROBLEMS
The gun does not spray when the
triggering lever is actuated.
Irregular spraying results
7KH WDQN FDQQRW EH VFUHZHG R 
10.1 Disconnect the spray gun from the air supply.
10.2 Empty the product out of the spray gun into a suitable container.
10.3 Pour the required quantity of a thinner suitable for cleaning (0.5 L) into the tank.
10.4 Close the tank and reattach the spray gun.
10.5 Spray the solvent into a suitable catch container.
Make sure that the positioning regulator (9) is completely closed to prevent atomization of the solvent.
Otherwise, this could result in dirtying of the immediate environment.
Do not completely immerse the spray gun in the solvent, but rather clean it with a soft brush or a cloth instead.
 /XEULFDWH WKH DLU YDOYH URG RFFDVLRQDOO\ :KHQ \RX DUH ÀQLVKHG ZLWK WKH ZRUN RU DUH WDNLQJ D EUHDN KDQJ
the spray gun on the special hook.
 1HYHU XVH H[FHVVLYH IRUFH ,I LPSURSHU WRROV HJ D SLSH ZUHQFK JDV EXUQHU HWF DUH XVHG WKH ZDUUDQW\
is voided. In many cases, orderly repairs can only be carried out using special tools. In such cases, limit
yourself to determining the cause of the problem and leave the repair work to the technical department of
your sales partner.
BDA_Druckbecherpistole_HRS2.indd 15
8 – RISKS
9 – TROUBLESHOOTING
CAUSES
No supply
Supply hose soiled or clogged
Residual pressure in the tank
10 – MAINTENANCE AND CARE
CORRECTIVE MEASURES
Open the manual regulator (19).
Clean all lines and the spraying
nozzle. Do not tilt the spray gun at
an angle greater than 45°.
Pull the ring of the safety valve
(41).