Noise Level; Using The Device - Würth HRS2 Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
The equivalent continuous acoustic pressure level, calculated on the A-scale, is measured at a horizontal
distance of 50 cm. It is < 80 dB(A) for bituminous products while spraying.
6.1 Supply, see Item 3.2.
6.2 Pneumatic connection of air supply, see Item 3.1.
6.3 Press the trigger and point the spray gun at the object to be treated at distance of 10 to 30 cm.
6.4 Do not tilt product by more than 45°.
 :KHQ \RX KDYH ÀQLVKHG \RXU ZRUN GLVFRQQHFW WKH JXQ IURP WKH DLU VXSSO\ DQG KDQJ LW RQ WKH VSHFLDO
hook.
7.1 Setting the product quantity (Fig. 5)
9
Fig. 5
7.2 Setting of the product atomization (Fig. 6)
Fig. 6
14
BDA_Druckbecherpistole_HRS2.indd 14
5 – NOISE LEVEL
6 – USING THE DEVICE
7 – SETTING
Turn the positioning regulator (9) clockwise to gradually reduce the
SURGXFW ÁRZ 7XUQ WKH SRVLWLRQLQJ UHJXODWRU FRXQWHUFORFNZLVH WR LQFUHDVH
WKH SURGXFW ÁRZ
9
:KHQ PDNLQJ WKH VHWWLQJ PDNH VXUH WKDW WKH SUHVHWWLQJ LV QRW H[FHHGHG
Otherwise there is a risk that the positioning regulator could be ejected
by the spring.
:KHQ XQVFUHZLQJ HQVXUH WKDW \RX GR QRW JR SDVW WKH VSHFLÀHG
PD[LPXP OLPLW
Be sure not to close the manual regulator (19) completely, as otherwise
the gun could smear.
Turn the manual regulator (19) clockwise so that the air passage gradually
closes. This decreases the atomization (it becomes coarser).
Turn the manual regulator (19) counterclockwise so that the air passage
19
RSHQV JUDGXDOO\ 7KLV LQFUHDVHV WKH DWRPL]DWLRQ LW EHFRPHV ÀQHU 
14.03.13 13:28
Tabla de contenido
loading

Este manual también es adecuado para:

0891 130

Tabla de contenido