1. Installation of the Clima Control
Basic Plus
1. Mount the TechGrow Clima Control Basic Plus on
the wall with the supplied mounting kit, but not near
a water pipe or drain.
2. Mount the Temp Probe, preferably about one meter
above the floor.
3. Make sure the rocker switch is set to "OFF".
4. Plug the plug(s) of the fan(s) into the outlet(s) of the
Clima Control Basic Plus.
5. Plug the Clima Control Basic Plus into an electrical
outlet.
6. Ready!
2. Operation of the Clima Control
Basic Plus
The Clima Control Basic Plus controls the temperature in
your room. The fan control works on the basis of the set
minimum fan speed "BOX MIN", maximum fan speed
"BOX MAX", temperature and hysteresis.
Example
If the desired temperature is set to 27 °C and the
hysteresis is set to 2 °C, the temperature can be between
25 °C and 29 °C (27 °C - 2 °C / 27 °C + 2 °C).
If the temperature is below the set temperature minus
hysteresis (in this example, below 25 °C), the fan runs at
the set "BOX MIN" speed.
If the temperature is above the set temperature plus
hysteresis (in this example, above 29 °C), the fan runs at
the set "BOX MAX" speed.
If the measured temperature is equal to the set
temperature (in this case 27 °C), the fan runs at idle
speed (see section 5.5).
Within the set hysteresis range (+/- 2 °C), the speed is
automatically reduced to the set "BOX MIN" speed or
increased to the set "BOX MAX" speed.
In the event of a sensor failure, the fan speed increases
to the maximum speed ("MAX").
2.1 Automatic functions
Depending on the settings, the fans are automatically
controlled. After activation of the Clima Control Basic
Plus the connected fans always start at full speed (for 1
second), to guarantee that your fan starts no matter how
____________________________________________________________________________________________________________________________
TechGrow
| Innovative Growing Solutions
low the "BOX MIN" is. After setting the desired
temperature, the Clima Control Basic Plus will
always maintain this temperature.
3. Connecting sensors or other
devices
The only sensor suitable for the Clima Control Basic Plus
is the Temp Probe. This sensor is preassembled and
interchangeable.
It is not possible to connect additional sensors or other
equipment to the Clima Control Basic Plus.
4. LED display
The LED display of the Clima Control Basic Plus displays
the current temperature.
After adjusting the preferred temperature, the display
will show the new setting for 3 seconds.
In the event of a sensor failure, "-" is displayed.
5. Control and set the Clima Control
Basic Plus
5.1 Set minimum fan speed
Turn the "TEMP" temperature knob all the way up to 45
°C. Set the rocker switch to "AUTO". The fan starts (the
fan must be switched on).
Now set the minimum fan speed to the desired level by
turning the "BOX MIN" knob.
5.2 Set maximum fan speed
Now, turn the "TEMP" temperature knob to 10 °C and
set the desired maximum fan speed by turning the "BOX
MAX" knob.
5.3 Temperature settings
Set the desired room temperature by turning the
"TEMP" knob. The set value is displayed for 3 seconds.
After that, the current temperature will be displayed.
5.4 Hysteresis
Set the hysteresis by turning the right rotary knob to the
desired value (1 ° C - 7 ° C).
10