Features
120 Amp SI* Automatic Charging Relay (ACR)
*Starting Isolation
• Automatically combines batteries during charging,
isolates batteries during engine cranking and
when not charging
• Allows temporary isolation of house loads from
engine circuit during engine cranking to protect
sensitive electronics
• Supports high-output alternators up to 120 Amps.
• Ignition protected-safe for installation aboard
gasoline powered boats
• Under voltage lockout-will not close when the
lower battery is below 10.8V at 12V operation or
21.6V at 24V operation
• Built in LED light indicates when batteries are
combined
• Meets external ignition protection requirements.
• Waterproof rated IP67—temproary immersion for
30 minutes
• Designed for 12 or 24 volt systems.
• Senses charge source on either battery bank
e
-Series, Dual Circuit Plus™ Battery Switch
• Switches two battery banks simultaneously
with one simple ON/OFF switch while maintaining
battery bank isolation, minimizing the risk of a dead
start battery
• The COMBINE BATTERIES function offers the
ability to combine two battery banks in the event of
a low battery
• Meets external ignition protection requirements.
Specifi cations
120 Amp SI ACR
12 Volt
24 Volt
Continuous Rating
120 Amps
120 Amps
Intermittent Rating
210 Amps
210 Amps
Inrush Rating
280 Amps
280 Amps
Maximum Cable Size
1/0 AWG
1/0 AWG
Terminal Stud Size
3/8"16 (M10) 3/8"16 (M10)
Maximum Torque
140 in-lbs
140 in-lbs
Relay Contact Position
-Combine
(30 sec.) 13.6 Volts
27.2 Volts
(2 min.)
13.0 Volts
26.0 Volts
-Open Low (10 sec.) 12.35 Volts
24.7 Volts
(30 sec.) 12.75 Volts
25.5 Volts
-Open High
16.0 Volts
30.0 Volts
Dual Circuit Plus™ Battery Switch
Continuous Rating
300 Amps
Intermittent Rating
525 Amps
Inrush Rating
1,500 Amps
System Voltage
up to 48 Volts
Cable Size
4/0 AWG
Terminal Stud Size
3/8"16 (M10)
Maximum Torque
140 in-lbs
Regulatory: CE marked for ignition protection,
meets ISO 8846 ignition protection, and SAE J1171
external ignition protection requirements, Rated IP67.
Produits électriques marins
ADD A BATTERY Dual Circuit System
PN 7650
Particularités
120 Amp SI* Automatic Charging Relay (ACR)
*
Isolement au démarrage
• Il combine automatiquement les batteries pendant la
charge, les isole pendant le démarrage du moteur et
pendant qu'elles ne chargent pas.
• Permet l'isolement temporaire des charges
domestiques du circuit du moteur pendant son
démarrage pour protéger les composants
électroniques sensibles.
• Tolère les hauts rendements des alternateurs jusqu'à
120 A.
• Il satisfait les exigences de protection d'allumage
externe.
• Il ne fermera pas quand la tension de la batterie
la moins chargée est inférieure à 10,8 V
(application de 12 V) ou 21,6 V (application de 24 V).
• Diode LED incorporée pour indiquer que les batteries
sont combinées.
• Étanchéité du niveau IP67—immersion temporaire de
30 minutes.
• Conçu pour les systèmes de 12 ou 24 V.
• Détecte la source de charge d'une rangée de
batteries.
e
-Series, Dual Circuit Plus™ Battery Switch
• Commute deux groupes de batteries simultanément,
au moyen d'un simple commutateur MARCHE/ARRET,
tout en maintenant l'isolement du groupe de batteries.
• Combine deux groupes de batteries en cas de
batterie à faible démarrage.
• Il satisfait les exigences de protection d'allumage
externe.
Fiche technique
120 Amp SI ACR
12 V
24 V
Tolérance en continue 120 A
120 A
Tolérance intermittente 210 A
210 A
Tolérance par coup
280 A
280 A
Taille de câble maximale 1/0 AWG
1/0 AWG
Taille de cosse mâle
3/8 po 16 (M10) 3/8 po 16 (M10)
Couple de serrage
140 lb/po²
140 lb/po²
maximal
Position des contacts du relais
-Combinée (30 s)
13,6 V
27,2 V
(2 mn) 13,0 V
26,0 V
-Ouvert bas (10 s)
12,35 V
24,7 V
(30 s)
12,75 V
25,5 V
-Ouvert élevé
16,0 V
30,0 V
Dual Circuit Plus™ Battery Switch
Tolérance en continue
300 A
Tolérance intermittente 525 A
Tolérance par coup
1,500 A
Voltage
48 V
Taille de câble maximale
4/0 AWG
Taille de cosse mâle
3/8"16 (M10)
Couple de serrage maxima 140 lb-po²
Réglementation: Marqué CE pour la protection
d'allumage, respecte la norme 8846 de l'Organisation
de normalisation internationale liée à la protection
d'allumage, ainsi que les exigences de protection
d'allumage externe J1171 de la SAE, qualifi ée IP67.
Productos eléctricos marinos
ADD A BATTERY Dual Circuit System
PN 7650
Características
120 Amp SI* Automatic Charging Relay (ACR)
*
Aislamiento de Arrancada
• Combina automáticamente las baterías durante
la carga, aísla las baterías durante la arrancada del
motor y cuando no están siendo cargadas.
• Permite el aislamiento temporal de cargas de la
casa del circuito del motor durante la arrancada del
motor con el fi n de proteger los circuitos sensitivos.
• Soporta alternadores de salida alta hasta de
120 Amps.
• Satisface los requisitos de protección de ignición
externa.
• No se cierra cuando la batería baja está por debajo
de 10,8 voltios (operación a 12 V) ó 21,6 voltios
(operación a 24 V).
• LED integrado indica que las baterías están
combinadas.
• Clasifi cación impermeable IP67 — inmersión
temporal de 30 minutos.
• Diseñado para sistemas de 12 ó 24 voltios.
• Detecta la fuente de carga en cualquiera de los
bancos de baterías.
e
-Series, Dual Circuit Plus™ Battery Switch
• Commuta simultaneamente due gruppi di batterie
con un semplice interruttore ON/OFF, mantenendo
isolato il gruppo di batterie.
• Abbina i due gruppi di batterie in caso di diffi coltà di
avviamento della batteria.
• Satisface los requisitos de protección de ignición
externa.
Especifi caciones
120 Amp SI ACR
12 Voltios
24 Voltios
Clasifi cación continua
120 Amps.
120 Amps.
Clasifi cación intermitente 210 Amps.
210 Amps.
Clasifi cación de corriente 280 Amps.
280 Amps.
de entrada
Máximo tamaño de cable 1/0 AWG
1/0 AWG
Tamaño de terminal de
3/8"16 (M10) 3/8"16 (M10)
espárrago
Torsión máxima
140 lbs./pul. 140 lbs./pul.
Posición de contacto del relé
-Combinado (30 seg.) 13,6 Voltios 27,2 Voltios
(2 min.)
13,0 Voltios 26,0 Voltios
-Abierto bajo (10 seg.) 12,35 Voltios 24,7 Voltios
(30 seg.) 12,75 Voltios 25,5 Voltios
-Abierto alto
16,0 Voltios 30,0 Voltios
Dual Circuit Plus™ Battery Switch
Clasifi cación continua
300 Amps.
Clasifi cación intermitente
525 Amps.
Clasifi cación de corriente
1,500 Amps.
de entrada
Voltios
48 Voltios
Máximo tamaño de cable 4/0 AWG
Tamaño de terminal de
3/8"16 (M10)
espárrago
Maximum Torque
140 lbs./pul.
Regulatorio: Marcado CE para Protección de
Ignición, cumple con la regulación 8846 de ISO
para protección de ignición y con los requisitos
de proteccion de ignición externa J1171 de SAE,
Clasifi cación IP67.
Prodotti elettrici marini
ADD A BATTERY Dual Circuit System
PN 7650
Caratteristiche
120 Amp SI* Automatic Charging Relay (ACR)
*
Isolamento durante la fase di avviamento
• Combina automaticamente le batterie durante il
caricamento, isola le batterie durante l'avviamento
del motore e in assenza di carico.
• Assicura l'isolamento temporaneo dei carichi della
casa dal circuito del motore durante l'avviamento
del motore stesso, per proteggere le parti
elettroniche sensibili
• Supporta alternatori ad alta produzione fi no a
120 Amp.
• Conforme ai requisiti di protezione dell'accensione
esterna.
• Non si chiude quando il livello della batteria è inferiore
a 10,8 Volt (funzionamento a 12V) od a 21,6 Volt
(funzionamento a 24V).
• Spia incorporata, indica che le batterie sono combinate.
• Grado di impermeabilità IP67— immersione
temporanea per 30 minuti.
• Concepito per impianti a 12 o 24 volt.
• Rileva la fonte di carica su ogni serie di batterie.
e
-Series, Dual Circuit Plus™ Battery Switch
• Conecta dos bloques de baterías simultáneamente,
con un único interruptor de
CONEXIÓN/DESCONEXIÓN, manteniendo al mismo
tiempo el aislamiento de los bloques de baterías.
• Combina dos bloques de baterías en el caso de una
batería de arranque bajo.
• Conforme ai requisiti di protezione dell'accensione
esterna.
Specifi che
120 Amp SI ACR
12 Volt
24 Volt
Potenza nominale continua 120 Amp
120 Amp
Potenza nominale
210 Amp
210 Amp
intermittente
Potenza nominale di punta 280 Amp
280 Amp
Dimensione massima del cavo 1/0 AWG
1/0 AWG
Dimensione del perno
m10 (3/8"16) m10 (3/8"16)
terminale
Coppia di serraggio massima 140 in-lbs
140 in-lbs
Posizione di contatto del relé
-Combina
(30 sec.) 13,6 Volt
27,2 Volt
(2 min.)
13 Volt
26 Volt
-Aperto basso (10 sec.) 12,35 Volt
24,7 Volt
(30 sec.) 12,75 Volt
25,5 Volt
-Aperto alto
16 Volt
30 Volt
Dual Circuit Plus™ Battery Switch
Potenza nominale continua
300 Amp
Potenza nominale
525 Amp
intermittente
Potenza nominale di punta
1,500 Amp
Voltage
up to 48 Volt
Dimensione massima del cavo 4/0 AWG
Dimensione del pernom
3/8"16 (M10)
terminale
Coppia di serraggio massima 140 in-lbs
Normativa: Marchi CE per la protezione
dell'accensione, conforme ai requisiti della
protezione dell'accensione ISO 8846 e della
protezione dell'accensione esterna di SAE J1171,
Nominale di esercizio IP67.
loading

Resumen de contenidos para Blue Sea Systems ADD A BATTERY

  • Página 1 Marine Electrical Products Produits électriques marins Productos eléctricos marinos Prodotti elettrici marini ADD A BATTERY Dual Circuit System ADD A BATTERY Dual Circuit System ADD A BATTERY Dual Circuit System ADD A BATTERY Dual Circuit System PN 7650 PN 7650...
  • Página 2 éventuellement se décharger bien qu’une source de charge soit présente. Any Blue Sea Systems product with which a customer is not satisfi ed may be returned for a refund or • Le 120A SI ACR n’est pas destiné à transporter des courants de démarrage. Utilisez la position de replacement at any time.
  • Página 3 Garantía Garanzia Si un cliente no está satisfecho con algún producto de Blue Sea Systems, el puede ser retornado en cualquier Se un cliente non è soddisfatto di un qualsiasi prodotto della Blue Sea Systems, egli può rimandarcelo ed momento para obtener reembolso o reemplazo.
  • Página 4 120 Amp SI Automatic Charging Relay Dimensions GND SI LED 120 Amp SI Automatic Charging Relay Side and Bottom Knockouts Fuse Fusible Fusible Fusibile Remote LED LED à distance LED remoto LED remoto Start Key Clé de contact Llave de arranque Chiave di avviamento -Series, Dual Circuit Plus™...

Este manual también es adecuado para:

7650