Operation Instruction
Screw the output connector on the threaded connector (Fig. C). Connect appropriate
soft tube on the output connector, and screw down by soft tube fastening clamp.
To increase the drawing speed, adjust the pump into dirty water mode according to
the drawing area condition. When it is dirty water mode, the flow is greater and the
drawing speed is faster, and when it is under clean water mode, the water in the area
can be drawn to the lowest drawing level as shown in the nameplate.
As shown in the Figure B.
The max submersible depth (h1) stands for the max installation water depth of the
pump (if the placing depth of the pump is deeper than the nominal value on the name-
plate, it may reduce the service life of the pump or let motor cavity inflow water.)
The conveying height (h2) stands for the height difference from water level to out-
let end of the water tube. So the pump should work within the range of max conveying
height.
G11/2"
G1"
1" water
screwed
screwed
tube
joint
joint
11/4"
water
tube
Locating
ring
Clean water
Dirty water