Pressure does not build up in the
appliance
Set nozzle to "High pressure".
Clean the nozzle.
Replace the nozzle.
Deaerate the appliance (see "Start-up")
Check water supply level (refer to technical
data).
Clean the sieve in the water connection.
Check all inlet pipes to the pump.
Contact Würth Master Service whenever re-
quired.
Pump leaky
3 drops of water per minute are permissible and
can leak out of the bottom of the appliance. In
case of more serious leaks, contact Würth Master
Service.
In case of more serious leaks, have the appli-
ance checked by Würth Master Service.
Pump is vibrating
Check suction pipes for water and detergent
and ensure that they are leak-proof.
Close dosing valve for detergent to operate
the machine without detergent.
Deaerate the appliance (see "Start-up")
Contact Würth Master Service whenever re-
quired.
Detergent is not getting sucked in
Set nozzle to "CHEM".
Check/ clean detergent suction hose with filter.
Open or check/clean detergent dosing valve.
Contact Würth Master Service whenever re-
quired.
Accessories and Spare Parts
– Only use accessories and spare parts which
have been approved by Würth. The exclusive
use of original accessories and original spare
parts ensures that the appliance can be oper-
ated safely and troublefree.
20
– Should the electrical tool fail in spite of our
thorough manufacturing and testing proce-
dures, have the repair performed by a Würth
Master Service. In Germany you can contact
Würth Master Service free of charge on
0800-WMASTER (0800-9 62 78 37) or in
Austria on 0800-20 30 13. For all queries
and spare part orders, always state the item
number according to the electrical appliance's
type plate.
– A copy of the current spare parts list for this
high-pressure cleaner can be downloaded via
the internet at
http://www.wuerth.com/partsmanager. Al-
ternatively this can be requested from your lo-
cal Würth branch.
Guarantee
– For this Würth high-pressure cleaner, we offer
a guarantee in accordance with the statutory/
country-specific provisions from date of pur-
chase (invoice or delivery note is required as
proof). Any damage that has occurred will be
resolved by replacement delivery or repair.
– Damages that can be traced to natural wear,
overload or improper handling are excluded
from the warranty coverage.
– Complaints can only be accepted if the high-
pressure cleaner is returned fully assembled to
a Würth branch, your Würth Sales Represent-
ative or Würth Master Service.
Disposal
Electrical devices, accessories and pack-
ages should be recycled.
Do not dispose of electric devices in the
regular waste!
EU countries only:
As per the European Directive 2002/
96/EG regarding used electric and
electronic devices and their implemen-
tation into national law, electric devices
that are no longer usable must be collected sepa-
rately and recycled.
GB - 7