Machine configuration
Code
UdL Up/Down lock
On: The Up/Down buttons at the torch of the i-LTG/i-LTW series are locked dur-
ing the welding process (I>0).
Powermaster LED 3
PL3
(freely allocatable)
Powermaster LED 4
PL4
(freely allocatable)
TPr
Torch protect
On: When an i-LTG/i-LTW series torch is used, only one welding current with
Tor
max. torch capacity can be set at the welding unit.
TPd Setting the torch ID
Each torch in the i-LTG/i-LTW has a specific torch identification number. This
torch ID is coupled to the load capacity of the torch, which is required for the
torch protection (tPr) function in the TIG operating mode.
Setting the torch ID is, for example, required when the torch PC board is
exchanged
 Select the appropriate ID for the torch according to the table and transfer it
to the torch module by saving.
Tab. 2:
Machine configuration menu
Fuse options
Parameter
Mains fuse
value
230 V
16*
16F
13
13F
10
10F
04.19
Parameter
max. current I
TIG
16A
200A
16A
200A
13A
190A
13A
190A
10A
180A
10A
180A
Standard
value
OFF
2.E
---
OFF
see "Setting the torch ID" on Page 38
Parameter
value
1
MMA
25*
180A
25F
180A
20
160A
20F
160A
Tab. 3:
125A
125A
i
909.4039.9-03
Setting range
OFF - On
all relevant
Secondary parameters
all relevant
Secondary parameters
OFF - On
Mains fuse
115 V
25A
25A
20A
20A
Fuse options
) Factory setting
*
The "F" label indicates a fuse character-
istic that reduces the welding current
earlier to prevent fast fuses from trip-
ping.
Mode
x
x
x
x
x
max. current I
1
TIG
MMA
180A
140A
180A
140A
170A
125A
170A
125A
- 37 -