WISE) only until cycle indicator points to the desired position
1. Remove valve cover by depressing the two
tabs on the sides of the cover and lifting the
front of the cover up and off.
2. Rotate cycle indicator (COUNTERCLOCK-
WISE) to the BACKWASH position.
3. Fill the softener/conditioner tank with water.
a. With house water supply off, open the
SourceSelect™ bypass valve.
b. Open water supply valve very slowly to
approximately ¼ open position.
4. When all of the air has been purged from
the tank (water begins to flow steadily from
the drain), open the main water supply all the
way. Allow water to run to drain until clear.
5. Turn off water supply and let the unit stand
for about five minutes to allow all trapped air
to escape from the tank.
6. Add the initial amount of water to the brine
tank manually with a bucket or a hose. Add
approximately 3 gallons of water to the brine
tank.
7. Slowly turn the water supply valve complete-
ly open. Place the conditioner into operation
by slowly turning the cycle indicator COUN-
TERCLOCKWISE to the BRINE/SLOW
RINSE position.
8. With conditioner in this position, observe the
STEP 5 CONNECT ELECTRICAL
Plug transformer into a 110 VAC outlet that is
NOT controlled by a wall switch. Connect the
plug of the transformer into the Transformer Plug
Receptacle located at the bottom of the control
housing (see Figure 1 on page 11).
STEP 6 PROGRAM THE VALVE CONTROL
KS5 AND KS10 PROGRAMMING:
1. Time of Day Setting
Open the access door to access the jumper
settings. The jumper should be on the TIME
jumper. Set the time of day to the nearest
hour by pressing the black TIME SET button.
PM hours are indicated by a light next to the
letters PM on the display window.
NOTE: The unit is factory-set to regener-
ate at 2:00a.m. If you prefer to have the unit
regenerate at an earlier or later time, simply
set the current time of day accordingly (e.g.,
to have the unit regenerate at 4:00a.m. – two
hours later - set the clock two hours earlier
than the actual time of day. If it is actually
2:00 p.m., set the time to 12:00 p.m.). Make
13 • 02/17 KPWS
water level in the brine tank for several min-
utes to check that the level is going down. If
water level does not recede, then make sure
the brine line fittings are tight and no air can
leak intothe fitting connections.
9. Advance the cycle indicator to the FAST
RINSE position. Let conditioner run in this
position for a minute or so.
10. Advance the cycle indicator to the REFILL
position. Hold this position until water starts
to flow through the brine line into the brine
tank.
11. Advance the cycle indicator COUNTER-
CLOCKWISE to the REGENERATION
COMPLETE position and run water from a
nearby faucet until the water is clear. Pro-
ceed to Step 5 Connect Electrical.
KS15HE CONTROLLER
CONTROL DEL SISTEMA KS15HE
Cycle Indicator
REGENERATION COMPLETE
PM
FIGURE 2 • FIGURA 2
sure the Timer Locking Pin is always in the
horizontal position during operation.
2. Hardness Setting
Move the jumper to the pins next to the word
HARDNESS. Press the black TIME SET
button until the hardness of the incoming
water supply is displayed. NOTE: The factory
default is 18 GPG (Grains Per Gallon). It is
a good idea to set your hardness a few grains
higher than your actual hardness because
hardness can vary throughout the year.
Check with your local water supply company
or municipality to find out the hardness in
your area.
Time of Day
Time of Regen
Hardness
Salt Amount
Capacity
Regen Time
Remaining
SET
REGEN
Regen Button
Tabla de contenido
loading

Este manual también es adecuado para:

Ks10Ks15heKs64he

Tabla de contenido