Important Parts Of Your Ifill Oxygen Cylinder - Sunrise Medical iFill DeVilbiss PD1000A Serie Guía De Instrucciones

Cilindro de oxígeno con aparato de regulación integrado/ con refulador de flujo continuo
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

E N G L I S H

IMPORTANT PARTS OF YOUR IFILL OXYGEN CYLINDER

1
PD1000 SERIES
1. Cannula Fitting– Use this fitting to attach the cannula to
your iFill cylinder.
2. Rotary Selector– Use this to select your prescription set-
ting.
3. Oxygen Fill Connection – Use this connection to attach the
cylinder to the DeVilbiss iFill Personal Oxygen Station.
NOTE–Your iFill oxygen cylinder can only be filled with the
DeVilbiss iFill Personal Oxygen Station.
4. Oxygen Contents Gauge– Indicates the remaining pressure
in the oxygen cylinder. When this gauge falls into the red
section, you should switch to a new cylinder.
5. Hydrostatic Test Date - Contact your homecare provider
or the cylinder manufacturer for details.
6. High-Pressure Oxygen Cylinder – Portable oxygen delivery
tank.
7. • PulseDose Indicator– Either green or red light illuminates
each time the unit pulses oxygen.
• Normal Battery Indicator– A flashing green light indicates
that there is sufficient battery power.
8. • Low Battery Indicator– A flashing red light indicates that
there are 4 - 8 hours of battery life remaining. The low
battery indication time may be reduced when using
NiMH batteries.
2
9 (on top)
8
7
4
5
6
PD1000A series
7
2
(on rear)
3
535-CF series
• Change Battery Indicator– A constant red light indicates
that the battery should be changed immediately. Unit can
be used only in continuous flow mode until new batter-
ies are installed.
9. Battery Door– Use only a standard "AA" Alkaline or NiMH
batteries.
535-CF SERIES
1. Cannula Fitting– Use this fitting to attach the cannula to
your iFill cylinder.
2. Rotary Selector– Use this to select your prescription set-
ting.
3. Oxygen Fill Connection – Use this connection to attach the
cylinder to the DeVilbiss iFill Personal Oxygen Station.
NOTE–Your iFill oxygen cylinder can only be filled with the
DeVilbiss iFill Personal Oxygen Station.
4. Oxygen Contents Gauge– Indicates the remaining pressure
in the oxygen cylinder. When this gauge falls into the red
section, you should switch to a new cylinder.
5. Hydrostatic Test Date - Contact your homecare provider
or the cylinder manufacturer for details.
6. High-Pressure Oxygen Cylinder – Portable oxygen delivery
tank.
I M P O R TA NT PA R T S
1
3
A-535-CYL
Tabla de contenido
loading

Tabla de contenido