Direct current
Measuring
Resolution Accuracy
range
200 μA
0.1 μA
2 μA
1 μA
20 mA
0.01 mA
200 mA
0.1 mA
2
10 mA
10 A*
0.01 A
Overload protection: μA and mA range is protected
by F 250 mA / 690 V.
10 A range is protected by F 10 A / 690 V.
* Observe the maximum switch-on duration for the
10 A range!
Alternating current measurement
Set the selector switch measurement range to
A
.
~
Set M button [8] to AC.
Connect the black measuring lead to the COM so-
cket [5] and the red measuring lead to the right
socket (up to max. 200 mA).
Attention!
For measurements above 250 mA, the 10 A
socket [7]must be used.
Connect the measuring leads to the test object.
3 The multimeter automatically searches for the
most favourable measurement range.
Read the measurement result from the dis-
play [1].
Attention!
To protect the device against overheating, allow a
pause of 30 minutes for cooling after measuring
for a period of no more than 30 seconds.
± 1.0 % of the
measured value +
3 digits
± 1.2 % of the
measured value +
5 digits
Alternating current
Measuring
Resolution Accuracy
range
200 μA
0.1 μA
2 μA
1 μA
20 mA
0.01 mA
200 mA
0.1 mA
2
10 mA
10 A*
0.01 A
Overload protection: μA and mA range is protected
by F 250 mA / 690 V.
10 A range is protected by F 10 A / 690 V.
* Observe the maximum switch-on duration for the
10 A range!

Resistance measurement

Set the selector switch measurement range to
Connect the black measuring lead to the COM
socket [5] and the red measuring lead to the
 A socket.
Connect the measuring leads to the test object.
3 The multimeter automatically searches for the
most favourable measurement range.
Read the measurement result from the dis-
play [1].
Resistance
Measuring
Resolution
range
200 Ω
0.1 Ω overvol-
tage protection:
250 V AC /
DC
2 kΩ
0.001 kΩ
20 kΩ
0.01 kΩ
200 kΩ
0.1 kΩ
2 MΩ
0.001 MΩ
20 MΩ
0.01 mΩ
Measuring voltage: 0.25 V.
Overvoltage protection: 600 V AC / DC < 30 s.
± 1.3 % of the
measured value +
3 digits
± 1.5 % of the
measured value +
5 digits
Accuracy
± 1 % + 5
digits
± 1 % + 5
digits
± 1.8 % + 5
digits