Operation Instructions - Standard Operation; Cooling; Heating - LG PREMTC00U Manual De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

DESCRIPTION
8
Function
Icon
Current temperature
- Display current room temperature.
Cooling set point temperature
Temperature
- Temperature set point for cooling operation.
Heating set point temperature
- Temperature set point for heating operation.
Displays current fan speed
POW : Fan speed - Power
AUTO : Fan speed - Auto
Fan speed
HI : Fan speed - High
MED : Fan speed - Medium
LO : Fan speed - Low
SLO : Fan speed - Weak
Set back operation mode
- Controller operates set back operation.
Controller
mode
Override mode
- Occupied/Unoccupied state change.
Command received from central controller or outdoor unit.
Slave indoor unit on a heat pump system prevents changing to a mode
not compatible with the current outdoor unit mode.
Product
state
Outdoor unit running.
monitoring
Indoor unit pre-heating operation running.
Defrost operation running.
Override timer setting step.
Function
Setback cooling / heating temperature setting step.
setting
It is displayed when is setting.
Description

OPERATION INSTRUCTIONS - Standard Operation

OPERATION INSTRUCTIONS - Standard Operation
Press
button several times until the
desired mode is selcected.
Whenever pressing the button, the selected
operation mode is changed as Auto ->
cooling -> Dehumidification -> Heating -> Fan
-> Auto··· .

Cooling

Heating

1
Adjust the desired temperature by
pressing
buttons.
9
!
NOTE
• Setting temperature range is as below.
- Cooling : 64°F ~ 86°F(18°C ~ 30°C)
60°F ~ 86°F(16°C ~ 30°C)
(For some models)
- Heating : 60°F ~ 86°F(16°C ~ 30°C)
h If connecting to indoor unit with
dual set point function.
Cooling : 50 ~ 99 °F (10 ~ 37.5 °C)
Heating : 40 ~ 90 °F (4 ~ 32 °C)
• Heating mode is not available for
cooling exclusive models.
Cooling mode
Set temperature is lower than room
temperature.
Temp[°F]
Room temp[°F]
Set temp[°F]
Heating mode
Set temperature is higher than room
temperature.
Temp[°F]
Set temp[°F]
Room temp[°F]
Tabla de contenido
loading

Tabla de contenido