Phase 6: Estimated capacity
IMPORTANT
Never change this value.
Should this accidentally happen, refer to the related column on the table.
• The system Exchange capacity is shown on the display
in kg CaCO3 removed before regeneration is needed.
• The value results from the system size and salt consumption
L-S-H.
• The capacity shown on the display results from standard
calculation conditions.
• Exchange capacity shows the system potentials and for
timer 740 it cannot be changed.
• In order to change exchange capacity on timer 760, press SET to have the default capacity flash.
Use UP and DOWN to increase up to the desired capacity.
• Press SET to confirm the setting and move to the next parameter.
• If you use timer 740, the programming is complete.
The timer will take you back to normal operating mode.
Phase 7: Enter hardness
• Enter the hardness of incoming raw water.
• The default hardness value is 350 mg (35 French degrees °F)
• To change hardness, press SET in order to have the setting flash.
Use UP and DOWN to increase/decrease the desired hardness value.
• Press SET to confirm.
• The programmer will take you to normal operating mode.
IMPORTANT
If the display shows fixed values "1.01-1.02-1.03", blow air inside the turbine for a few seconds to
restart the programmer.
________________________________________________________________________________
Water softener ELETTRONIC with AUTOTROL digital head logix
(only for timer 760 with volumetric control)
23