Programming
Table 5 - Continued
Menu
Parameter
Settings
Internal
Setpoint
Setpoints
External
Setpoint
Sub Menu
Parameter
Motor Phase
Connection
Type
Motor Type
Motor
Service Factor
Amps
Min Frequency
Max
Frequency
Max Sensor
Sensor
Value
PN957 (3/23/20)
Unit of
Measure
Default
PSI
60 PSI
PSI
40 PSI
Unit of
Default
Measure
_
1
–
3 wire
–
Subm
A
00.0 A
Hz
30 Hz
Hz
60 Hz
PSI
100 PSI
Value
Min
Max
Main pressure setpoint used. Sets
Max
main system operational pressure.
Sensor
This parameter is accessed here,
15 PSI
Value
through PSI Preset button, or by
minus 3
pressing Enter button while in
PSI.
Constant Pressure operation.
Second pressure setpoint. When
another pressure setting is desired
Max
other than Internal Setpoint.
Sensor
Additional programming needed in
I/O section. Requires an external
15 PSI
Value
minus 3
switch or timer to be wired to
PSI.
digital input terminals. It is only
active when there is voltage present
at the digital input terminals.
Min
Max
Selects phase of motor to be
operated. An additional sub menu
1
3
will appear, based on phase
selection, to select proper motor
type.
Wire type for 1 phase motor
operation only. Can only access by
3 wire
2 wire
first setting Motor Phase parameter
to 1 Phase.
Motor type for 3 phase motor
Above
operation only. Can only access by
Subm
Gnd
first setting Motor Phase parameter
to 3 Phase.
Per
Service factor amps (max. load) of
drive
motor the Drive is operating. Sets
00.0 A
and
maximum allowed amps at output
motor
of Drive. See Table 8 for values.
1 below
Minimum frequency (speed) motor
30 Hz
Max
will run.
Hz
Maximum frequency (speed)
1 above
motor will run. Up to 80Hz is only
Min
80 Hz
available on submersible 3-phase
Hz
motors (when motor is 2x the HP
of pump).
Maximum pressure value of
transducer sensor used with Drive.
100 PSI 300 PSI
Only change if different transducer
is used with Drive, other than 100
PSI max scale.
15
15
Description
Description