Initial Startup

Initial Startup and
Programming Procedures
Ensure that the cover is installed before operating
the PENTEK INTELLIDRIVE
Most installations will only require the initial
startup settings. However, the installer may need
to set additional parameters. Information about
accessing all parameters, explanations of their
functions, and procedures for changing parameter
values, will be found later in this section.
Table 4 - Pentek Motor Service Factor Amps
Motor
PENTEK Part
Type
Number
P42B0005A2-01
P42B0007A2-01
P42B0010A2-01
P42B0015A2-01
P42B0005A2-02
P42B0007A2-02
2-Wire
P42B0010A2-02
P42B0015A2-02
P42B0005A2
P42B0007A2
P42B0010A2
P42B0015A2
P43B0005A2-01
P43B0007A2-01
P43B0010A2-01
P43B0015A2-01
P43B0005A2-02
P43B0007A2-02
CS/CR
P43B0010A2-02
3-Wire
P43B0015A2-02
P43B0005A2
P43B0007A2
P43B0010A2
P43B0015A2
P43B0020A2
P43B0005A3
P43B0007A3
P43B0010A3
3-Phase
P43B0015A3
P43B0020A3
P43B0030A3
P43B0050A3
PN957 (3/23/20)
.
®
Rating @
Service
230V
Factor
Amps
HP
1/2
4.7
3/4
6.2
1
8.1
1-1/2
10.4
1/2
5.1
3/4
6.1
1
8.0
1 1/2
10.6
1/2
4.7
3/4
6.4
1
9.1
1-1/2
11.0
1/2
4.8
3/4
6.0
1
7.3
1-1/2
10.9
1/2
4.5
3/4
5.7
1
6.8
1 1/2
10.7
1/2
4.9
3/4
6.3
1
7.2
1-1/2
11.1
2
12.2
1/2
2.9
3/4
3.9
1
4.7
1-1/2
6.1
2
7.6
3
10.1
5
17.5
1. Program the Drive: Apply power to the
PENTEK INTELLIDRIVE
in the display. Follow keypress sequence shown in
Figure 10.
NOTICE If Setup Guide does not appear, refer to
Drive Reset Procedure, Figure 20.
Figure 10 - Drive Setup Guide.
2. Select 80 Hz Operation, if necessary (See 60 Hz
to 80 Hz Operation for more information):
A. Press MAIN MENU button.
B. Follow the keypress sequence shown in
Figure 11.
Figure 11 - Select 80 Hz
(3-phase submersible operation only).