Electrical Safety; Residual Risks; Technical Data; Before Starting The Equipment - Scheppach LB2600E Traducción De Las Instrucciones Originales De Funcionamiento

Aspirador de hojarasca eléctrico
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
• Handle the unit with care. Clean the ventilation slits
regularly; keep to the maintenance instructions.
• Do not overload your device. Work only within
the indicated range of performance. Do not em-
ploy any low power machines for heavy work.
Do not use your device for purposes for which it has
not been designed.
• Do not attempt to repair the appliance yourself unless
you have specific training to do so. Leave any work not
listed in this manual to our Service Centre.
• Check the grass bag regularly for wear or damage.

Electrical safety:

CAUTION! The following states how to avoid accidents
and injuries due to electric shock:
• Make sure that the mains voltage is compatible with
the information of the label.
• Connect the device, as far as possible, only to a plug
socket with a groundfault circuit interrupter (g.f.c.i switch),
with a rated residual current at not more than 30 mA.
• Check the device and the power cable with plug for
damage before every use. Avoid bodily contact with
grounded parts (e.g. metal fences, metal post).
• The coupling of the extension cord must be protected
against splashed water, it must consist of rubber or be
surrounded by rubber. Employ only extension cords
which are stipulated for use in the open air and are
marked accordingly. The flexible lead crosssection
of the extension cord must at least 1.5 mm
roll out the cable drum completely before use. Check
the cable for damage.
• Keep the cable away from the field of action and basi-
cally play it out behind the operator.
• Use the tension relief provided for the fixing of the
extension cord.
• Do not carry the device by the cable. Do not use the
cable to pull out the plug from the plug socket. Protect
the cable against heat, oil and sharp edges.
• Damaged cables, coupling and plugs or connecting
leads not corresponding to specifications, must not
be employed. Remove the plug immediately from the
plug socket in case of damage to the mains cable.
Do not touch the mains power supply cable under
any circumstances until you have pulled the plug out
of the mains socket.
• If the power cable for this equipment is damaged, it
must be replaced by the manufacturer, a customer
service agent of the same or a similarly qualified per-
son in order to prevent hazards.
• Do not use the appliance if the on/off switch does
not work properly. Always have a damaged switch
repaired by our Service Centre.
• Before each use, check the power supply lead and
the extension cable for damage and ageing. Do not
use the equipment if the cable is damaged or worn.

Residual risks

Even if you use this electric power tool in accordance
with instructions, certain residual risks cannot be
rules out. The following hazards may arise in connec-
tion with the equipment's construction and layout:
1. Damage to hearing if no suitable ear protection is used.
2.Health damage caused by hand-arm vibrations if the
equipment is used over a prolonged period or is not
properly guided and maintained.
3.Remaining hazards can be minimized by following the
instructions in Safety Precautions, Proper Use and in
the entire operating manual.
Warning! This electric tool generates an electromag-
netic field during operation. This field can impair active
or passive medical implants under certain conditions. In
order to prevent the risk of serious or deadly injuries, we
recommend that persons with medical implants consult
with their physician and the manufacturer of the medical
implant prior to operating the electric tool.

6. Technical data

Rated input voltage
Input power
Protection class
Safety class
Air capacity
Air speed
Shredding rate
Content of the collection
bag
. Always
2
Sound pressure level (L
Uncertainy K
Sound power level measured
(L
)
wA
Sound power level guaran-
teed (L
Uncertainy K
Vibration at the handle (a
Vibration additional grip (a
Uncertainy K
Noise and vibration
Total vibration values determined in accordance with EN
61029.
Wear hearing protection!The effects of noise can
cause a loss of hearing. Total vibration values (vector
sum - three directions) determined in accordance with
EN 61029.

7. Before starting the equipment

Before you connect the equipment to the mains supply
make sure that the data on the rating plate are identical
to the mains data.
Warning!
Always pull the power plug before making adjust-
ments to the equipment.
Start up the equipment only when fully assembled.
Always inspect the power cable for damage before star-
ting up. The equipment may be used only if the cable is
in flawless condition.
230-240 V ~ 50 Hz
)
pA
pA
)
wA
wA
)
h
)
h
GB
3000 W
II
IPX20
11-13.5 m
/min
3
275 km/h
10:1
45l
86,3 dB(A)
3 dB(A)
104 dB(A)
100,3 dB(A)
3,57 dB(A)
2,765 m/s
2
2.765 m/s
2
1.5 m/s
2
17 І 64
Tabla de contenido
loading

Este manual también es adecuado para:

5911002901

Tabla de contenido