5.3 - CONNECTION TO ELECTRICAL SYSTEM
1 - Check that the voltage of the electrical system (mains) is the same as indicated on the ID
label of the machine.
2 - Check that the plug complies with local safety r
ground connection (earth).
3- Ensure that the outlet is protected by a "cut-out" (differential magnetic-thermal switch with
sensitivity of less than 30mA per 30ms) or that a device is pr esent which can test the ear-
thing circuit.
4 - Do not connect other appliances contemporaneously to the same power outlet.
5 - Insert the plug only after checking that the machine switch is in the OFF position.
6 - The standard plug for the 50 Hz version is:
Model SCHUKO 250 V - 16 A Dir ective CEE7-VII-DIN49441-2-AR2.
7 - Unroll the cord completely to avoid overheating.
8 - Do not crush on the power cor d.
9 - Do not use the high pr essure cleaner if the electric cable is damaged.
10- If the power cord is damaged, its r eplacement can be effected only by the technical servi-
ce personnel or by a qualified technician.
WARNING: IN CASE OF POWER F AILURE DURING USE OF THIS MACHINE, TURN
THE MACHINE POWER SWITCH TO THE OFF POSITION FOR SAFETY REASONS.
5.3.1 - CUT-OUT SWITCH (Only the United States)
This UL version high-pressure washer is equipped with a cut-out switch contained in the power
cable plug.
Said equipment provides extra protection against the risk of electric shock.
When replacing the plug or cable, use the same components including the cut-out device.
egulations, and that it is pr ovided with
11