REMEMBER
• Our taps must be installed by professional installers in accordance with current regulations and
recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer (see calculation
table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the frequency of
maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the tap to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be checked
at least once a year, and more frequently if necessary.
SETTINGS
• Battery-operated versions (ref. 452300 and 452310):
PROG
Detection distance - GAIN
Not
adjust.
• Mains supply (ref. 452150, 452159, 452565 and 452569):
Factory setting: "PROG 3"
PROG
Detection distance –
(fig. K)
GAIN (fig. L )
From 8 to 25cm
1
Rider on PC (fig. M)
From 8 to 25cm
3
Rider on PC (fig. M)
From 8 to 25cm
Rider on PC (fig. M)
9
From 25 to 60cm
Rider on PL (fig. M)
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the tap several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.
4 cm
2
2
2
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
Operation mode
1
st
detection = open
detection = close
nd
Operation mode
1
st
detection = open
nd
detection = close
1
st
detection = open
detection = close
nd
Presence open then
absence close
Time flow - TEMPO
60 seconds if no
2
detection
nd
Time flow - TEMPO
(fig. N)
30 mins if no 2
nd
détection
Can be adjusted from 30
to 100 seconds if no
2
detection
nd
/
Duty flush
24h
Duty flush
(fig. O)
24h
Can be adjusted to 12h
or OFF
24h
Can be adjusted to 12h
or OFF
24h
Can be adjusted to 12h
or OFF
12