Maintenance & Cleaning - Delabie 717510 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 11
OPERATION AND FEATURES
• Press the push-button control to open the valve.
• Timed automatic shut-off after ~7 seconds for basins (+/- 3 seconds according to the European standard EN-NF 816)
and ~30 seconds for showers (+5/-10 at 3 bar according to the European standard EN-NF 816).
• This product has been designed to withstand both thermal and chemical shocks in line with current regulations.
• Pressure: 1 - 5 bar (100 - 500kPa), we recommend 3 bar (300kPa).
FLOW RATE ADJUSTMENT (Fig. A, B, C, D page 2)
• Flow rate is pre-set in factory at 6 lpm at 3 bar, and is adjustable.
INSTALLATION
• Under no circumstances should the non-return valves integrated in the water inlets be removed (they are essential).
• Install the filters supplied exactly as shown in the diagrams.
THE INSTALLER MUST ENSURE:
• ENSURE THE CONNECTION WITH THE PANEL IS WATERTIGHT.
• CHECK THE WATERTIGHTNESS OF THE CONNECTION AT LEAST ONCE A YEAR AND AS OFTEN AS
NECESSARY.
If this advice is not followed, water may leak into the wall.
DELABIE cannot be held responsible for any ingress.
FOR FURTHER INFORMATION PLEASE CALL DELABIE TECHNICAL SUPPORT
UK: 01491 821821. ALL OTHER MARKETS: +33 (0)3 22 60 22 74.
REMEMBER
• Our valves must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer (see calculation
table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce the frequency
of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the valve to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be checked
at least once a year, and more frequently if necessary.
MAINTENANCE
We recommend an annual check of interchangeable cartridges: de-scale internal parts and replace worn or damaged
parts.
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the valve several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.
For the UK market only: Tel. 01491 821 821 - email: [email protected]
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: [email protected]
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com
EN
6
Tabla de contenido
loading

Este manual también es adecuado para:

717511717520717521717540

Tabla de contenido