Operating manual
Cold current/Background
current)
PULSE frequency
Down slope current.
Post-gas
HotStart
ArcForce
TIG PULSE
TIG SPOT
MMA PULSE
2T
4T
4T LOG
Ampere (unit)
Volt (unit)
Second or Hertz (units)
Percentage (unit)
Display switch A or V
Program menu access
Risk-reducing device
Sleep mode
HMI OPERATION AND DESCRIPTION OF ITS BUTTONS
Sleep Mode / Sleep Exit
This key is used to activate or exit the standby mode. Activation of the mode is not possible when the product is in welding
condition.
Note: When the power is turned on, the product starts in standby mode.
Welding process selection button
This button is used to select the welding process. Each successive press/release switches between the following welding
processes: TIG HF / TIG LIFT / MMA. The LED indicates the selected process.
Translation of the original
instructions
Second welding current or «cold» current in standard 4TLOG or in PULSE
mode
PULSATION frequency of the PULSE mode (Hz)
Down slope current to minimum current, I Stop (S) to prevent weld defects
and craters.
Duration for which gas is released after the arc has stopped. It protects the
weld pool and the electrode against oxidization when the metal is cooling (S).
Adjustable overcurrent at the beginning of the welding (%)
Overcurrent delivered to avoid sticking when the electrode enters the welding
pool
Pulse mode
Spot mode:
MMA process in PULSE mode
2 time torch mode
4 time torch mode
4 time LOG torch mode
Amperes unit for welding current settings
Volt unit for displaying welding voltage
Seconds or Hertz unit for time or frequency settings
Percentages unit for proportionate settings
Switches the display of voltage or current during and after welding
Access to configuration menu (SAVE, JOB, ...)
Standard picture symbol indicating the status of the VRD function
Sleep mode
PROTIG 201 DC FV
23