5. Fan Assembly. (cont.)
With the hanging bracket secured to the outlet box
and able to support the fan, you are now ready to
hang your fan. Grab the fan firmly with two hands.
Slide downrod through opening in hanging bracket
and let hanging ball rest on the hanging bracket.
Turn the hanging ball slot until it lines up with the
hanging bracket tab.
WARNING: Failure to align slot in hanging ball with
tab in hanging bracket may result in serious injury
or death.
Tip: Seek the help of another person to hold the
stepladder in place and to lift the fan up to you
once you are set on the ladder.
6. Wiring.
CAUTION: Be sure outlet box is properly grounded
and that a ground wire (GREEN or Bare) is present.
Make sure all electrical connections comply with
Local Codes or Ordinances and the National
Electrical Code. If you are unfamiliar with electrical
wiring or if the house/building wires are different
colors than those referred to in the diagram to the
right, please use a qualified electrician.
WARNING: If using this fan in a DAMP location,
this fan must be connected to a supply circuit that
is protected by a Ground Fault Circuit Interrupter
(GFCI) to reduce the risk of personal injury,
electrical shock or death.
When downrod is secured in place on the hanging
bracket, wire the RECEIVER with wire connectors
provided as shown in diagram at right.
Tip: While you are wiring, keep in mind that wires
must not obstruct receiver from sliding into
hanging bracket.
* Wrap each wire connector separately with
electrical tape as an extra safety measure.
Gently insert receiver (flat side up) into hanging
bracket and carefully push taped wire connectors
into outlet box. Allow antenna from remote
control receiver to hang outside of hanging
bracket.
white supply wire
black supply wire
blue
white
black
from fan
from receiver
black
white
blue
receiver
(wiring for receiver)
Modifications not approved by the party responsible for compliance could
void the user's authority to operate the equipment.
*NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
*
Reorient or relocate the receiving antenna.
*
Increase the separation between the equipment and receiver.
*
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
page 5
hanging bracket tab
hanging ball slot
ground (green
or bare)
ground (green
or bare)
white
black
from ceiling
from receiver
black
AC IN L
white
AC IN N
antenna