Timer Function - Brandson Equipment DC Motor 305022 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

6.3 Timer function

The appliance can be switched off at the set time using the timer function.
After pressing the "Timer" button, the time can be set by pressing the "+" and
"-" buttons on the remote control. (Cycle: 0-1-2-3-4-5-6-7-8-0 Hours) The time is
enabled once the indicator flashes 3 times.
If the set time shows 0, it means that the "Timer" function is disabled.
Example: If you want to set the timer to 5 hours, press the "Timer" button and
then the "+" button until the number "5" is shown on the display.
6.4 Temperature-dependent mode
Working range
Measuring interval
Temperature tol-
erance
When this function is switched on, the speed level changes based on the current
ambient temperature measured at the time this function was started.
For example, if the fan is switched to ECO mode with speed level 6, then the
speed level is changed based on level 6. If the speed level is manually changed
to level 8 with this function, then further speed adjustments are made based on
level 8 instead.
The automatic speed level adjustments now made are also based on the temper-
ature at which this function was started.
If, for example, the ambient temperature is 24°C when ECO mode is switched
on, it will henceforth be checked whether the ambient temperature has still
remained at 24°C. If the temperature now increases by 1°C according to the refer-
ence ambient temperature (24°C), the speed also increases by 1 step.
In the same way, if the temperature drops by -1°C according to the original refer-
ence ambient temperature, the speed level is lowered by 1 level.
Example:
English
10°C-40°C
every 11 seconds
+/- 1°C
33
Tabla de contenido
loading

Tabla de contenido