Maintenance & Cleaning - Delabie MONOFOOT 736102 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
OPERATION
• Foot control to open flow. Instant shut-off when the pedal is released. To prevent the risk of water hammer when
closing, limit the pressure using a pressure reducer.
• Mixer: the mixer's principle of operation enables the user to draw cold or mixed water from the outlet:
• Cold water flow from the pedal's initial range of motion, followed by progressively mixed water with the opening
of the hot water by pushing the pedal to the end of its range of motion, touching the floor.
INSTALLATION
• Thoroughly flush the pipes to remove any impurities before installing and commissioning the tap/mixer.
• Mixer: supply with cold water, and hot water at a maximum of 60°C (recommended: 45°C), balancing
the pressures (ΔP < 1 bar). Supply pressure: 10 bar maximum (recommended: 0.5 to 5 bar dynamic).
• Tap: supply with cold or mixed water (37°C).
• Attach the device using the 4 stainless steel screws, following the dimensions indicated.
REMEMBER
• Our mixers/valves must be installed by professional installers in accordance with current regulations
and recommendations in your country, and the specifications of the fluid engineer.
• Sizing the pipes correctly will avoid problems of flow rate, pressure loss and water hammer
(see calculation table in our brochure and online at www.delabie.com).
• Protect the installation with filters, water hammer absorbers and pressure reducers to reduce
the frequency of maintenance (recommended pressure from 1 to 5 bar maximum).
• Install stopcocks close to the mixer/valve to facilitate maintenance.
• The pipework, filters, non-return valves, stopcocks, bib taps, cartridge and all sanitary fittings should be
checked at least once a year, and more frequently if necessary.
MAINTENANCE
• Impurities coming from pipework can cause malfunctions:
• Floor installation: If the issue continues after cleaning the filters, order the repair pack ref. 753739
and replace the valve holder and seal.
• Wall-mounted installation: If the issue continues after cleaning the filters, order the repair pack ref. 753739
and replace the piston and O-rings.
CHEMICAL AND THERMAL SHOCKS
• This product has been designed to withstand both thermal and chemical shocks in line with current regulations.
MAINTENANCE & CLEANING
• Cleaning chrome, aluminium and stainless steel: do not use abrasive, chlorine or any other acid-based
cleaning products. Clean with mild soapy water using a cloth or a sponge.
• Frost protection: drain the pipes and operate the mixer/valve several times to drain any remaining water.
In the event of prolonged exposure to frost, we recommend taking the mechanisms apart and storing them indoors.
For the UK market only: Tel. 01491 821 821 - email: [email protected]
For all other markets: Tel. +33 (0)3 22 60 22 74 - email: [email protected]
13
After Sales Care Support:
The installation guide is available on: www.delabie.co.uk
The installation guide is available on: www.delabie.com