PULSE OUTPUTS

Features
· Max. input voltage: 30 V
· Max. input current: 27 mA
· Voltage drop at the active output: max. 2 V/27 mA
· Current through inactive output: max. 5 µA/30 V
· Max. reverse polarity voltage without destruction of outputs: 6 V
· Pulse duration: min. 5.5 ms (by max. pulse frequency 90 Hz)
· Pulse break: min. 5.5 ms, max. 2.0s
· Max. pulse frequency: 90 Hz
Note: The respective lowest pulse value of a meter can give a
pulse frequency higher than 10 Hz.
These frequencies are suitable for conversion to analogue signals.
If the meter is to be operated with system components (e.g. radio
module with pulse output), the next higher pulse value must be
set.
ed value range.
imal
Places shown after
decimal point
2
1
0
WDV / Molliné GmbH · Mönchstraße 11 · 70191 Stuttgart · Tel. 0711 / 35 16 95 - 20 · Fax 0711 / 35 16 95 - 29 · www.molline.de
Pulse value
Decadic
0.1 – 100 litres/pulse
Decadic
1 – 1000 litres/pulse
Decadic
10 – 10000 litres/pulse
English
Pulse value 1
Default
0,1
1
10
Pulse value 2
Default
1
100
1000