Spare Parts; Disposal Information - Renfert SILENT TC Guia De Inicio Rapido

Ocultar thumbs Ver también para SILENT TC:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
Empty Dust Drawer
After reaching a set time interval, a request appears to empty the dust drawer:
♦ An acoustic signal sounds 3 x.
EN
♦ Display dust drawer (26) lights up.
♦ The display (24) shows a container filling up.
Before removing the dust drawer, a filter cleaning function should be performed:
⇒ Press Enter key (27) for 2 seconds.
♦ The filter is cleaned (duration approx. 8 sec).
♦ The counter for recording the time interval is reset.
After the filter cleaning has finished:
⇒ Unlock the dust drawer with the clamp fastener (4a).
⇒ Pull the dust drawer (4) forward and empty.
⇒ Replace the dust drawer again until it locks into place.
⇒ Close the clamp fastener (4a).
If the dust drawer has been emptied without prior filter cleaning, the counter must be reset separately to
record the time interval.
⇒ Press the Enter key (27) (counter for recording the time interval is reset).
♦ Acoustic signal acknowledges the information.
♦ Dust drawer display (26) is deleted.
If the dust drawer is not emptied, the dust drawer (26) display will still light up. After switching the
device off and on again, a 3 x acoustic signal is used to indicate the emptying of the dust drawer.
To set the time interval, see Fig. D at the beginning of this document, or refer to the Instructions for Use
on the Internet.
Change Fine Filter
If the filter cleaning does not show sufficient effect (suction power has not improved), the fine filter must
be changed.
This is detected by the suction and indicated by "A" in the display.
If requested to change the fine filter or the suction performance does not improve substantially or
only for a short period, the fine filter must be changed soon.
Further operation can lead to damage to the device.
Perform filter cleaning before changing the fine filter.
When installing the fine filter please ensure that it is positioned correctly, otherwise leakages may result.
Please refer to the assembly instructions at the end of this document, which are also included with the
new fine filter.

Spare Parts

You can find components subject to wear and the spare parts on the
spare part list in the internet at www.renfert.com/p918.
Enter the following item number: 29350000.
The components excluded from the warranty (such as consumables
or parts subject to wear and tear) are marked on the spare part list.

Disposal Information

Within the European Union, units with this symbol should therefore not be disposed of in unsort-
ed domestic waste.
Please contact your local authorities for more information on proper disposal.