Functional check

DE
a) Check the display. If there is no display, check the
correct fitting and function of the batteries.
EN
b) Comfort mode
c) Select temperature menu T and adjust the temperature
FR
setpoint
to 29 °C (refer to the Operating
Instructions)
IT
d) The relay must be energized and thus the actuating
device activated within one minute. Flame symbol
ES
will appear on the display. If that is not the case:
· Check actuating device and wiring
NL
· The room temperature is possibly above 29 °C
SV
e) Reset the setpoint temperature
(standard value 19 °C or individual setting)
TR
f) Select the required operating mode
7
Reset
HU
User-defined data:
PL
Press the button behind the pin opening for at least one
second: this resets the user-specific settings to their default
CS
values (the heating engineer settings will not be changed).
The clock starts at 12:00. During the reset time, all sections
EL
of the display light up, enabling them to be checked.
All user-defined data plus the heating engineer settings:
Press the button behind the pin opening together with the
warmer and colder buttons for at least one second.
After this reset, the factory settings will be reloaded (also
refer to section "Factory settings" in the operating
instructions).
6/30
to the initial value
2015-02-28
8
Notes
· REA23 is an electric weekly programmable room
temperature controller
· The controller conforms to "Software Class A" and is for
use in "normal" pollution situation
· If the reference room is equipped with thermostatic
radiator valves, they must be set to their fully open
position
· The remote operation contact T1 / T2 must be wired
separately using a separate screened cable
· Ensure that the local regulations for electrical
installations are complied with
· External preliminary protection with max. C 10 A circuit
breaker is required in all cases
CE1G2216xx