Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

7.8.5.2 Submenu for configuration
Submenu for matching the input
pulses and display
Multiplication factor
Multiplication factor can be
programmed from 00.0001 to
99.9999.
The setting 00.0000 will not be
accepted
Division factor
Division factor can be
programmed from 01.0000 to
99.9999.
The setting <01.0000 will not be
accepted
Display mode
Calculation and display of the
frequency / speed in 1/s
Calculation and display of the
frequency / speed in 1/min
Decimal point setting
Decimal point
(determines the resolution)
0
0.0
0.00
0.000
Moving average
Moving average calculated
AVG 2
AVG 5
AVG 10 over 10 measurements
AVG 20 over 20 measurements
Start delay
Start delay
Programmable from 00.0 to
99.9 s
At the start of a measurement the
measurement results within this
time-period are ignored.
Waiting time
Waiting time
Programmable from 00.1 to
99.9 s.
This value specifies how much
time should elapse, after the last
valid edge, before zero is to be
displayed.
Page 12
no decimal place
1 decimal place
2 decimal places
3 decimal places
over 2 measurements
over 5 measurements
Display colour (for device 6.924.x113.xxB)
Display colour
Upper line
Lower line
Display colour
Upper line
Lower line
7.8.5.3 Preset 1
See below 7.8.6.5
7.8.5.4 Preset 2
See below 7.8.6.6
7.8.5.5 Preset 3, 4, 5 and 6
See below 7.8.6.7

7.8.6 Timer

7.8.6.1 Submenu for the Signal and
Control inputs
Menu for programming the signal
and control inputs
Input polarity
PNP: switching to Plus
for all inputs in common
nPn: switching to 0 V
for all inputs in common
Filter for the signal inputs Inp A and Inp B
for electronic control of the
signal inputs
for mechanical control of the
signal inputs(for control with
mechanical contacts)
Input mode Time measurement
Start: Edge to Inp A
Stop: Edge to Inp B
Start: 1. Edge to Inp B
Stop: 2. Edge to Inp B
red
red
red
green
www.kuebler.com